Active scissor-jack for seismic risk mitigation of building structures
نویسندگان
چکیده
منابع مشابه
Seismic Mitigation of Building Frames using Magnetorheological Damper (TECHNICAL NOTE)
The present study focusses on the damping force control of shear mode magnetorheological (MR) damper for seismic mitigations. Therefore, the semi-active MR damper which can control the vibration is analyzed both experimentally and numerically. Carbonyl iron is used as the magnetic particle and Castrol Magnetec oil as carrier fluid throughout the study. MR damper is designed and fabricated, and ...
متن کاملSeismic Mitigation of a Historic Masonry Building
This work presents an analysis of different proposals of rehabilitation of a masonry building, built around the beginning of the XX century for public schools, in the highest seismic risk zone of Argentine; and which was closed down after Mendoza`s Earthquake in 1985. The building has masonry walls of artisanal ceramic bricks and wood-framed roof but it does not have lateral ties. Currently, it...
متن کاملSeismic Response of Building Structures with Sliding Non-structural Elements
Interaction between a structure under base excitation and heavy non-structural elements that it supports is significant in the seismic analysis and design of the structure. Heavy non-structural elements may slide/rock under base excitation, and this dynamic action affects the seismic behavior of the supporting structure. Hence, in this study, a numerical model was presented to describe the seis...
متن کاملAN EFFICIENT METHOD FOR OPTIMUM PERFORMANCE-BASED SEISMIC DESIGN OF FUSED BUILDING STRUCTURES
A dual structural fused system consists of replaceable ductile elements (fuses) that sustain major seismic damage and leave the primary structure (PS) virtually undamaged. The seismic performance of a fused structural system is determined by the combined behavior of the individual PS and fuse components. In order to design a feasible and economic structural fuse concept, we need a procedure to ...
متن کاملSEMI-ACTIVE NEURO-CONTROL FOR MINIMIZING SEISMIC RESPONSE OF BENCHMARK STRUCTURES
This article presents numerical studies on semi-active seismic response control of structures equipped with Magneto-Rheological (MR) dampers. A multi-layer artificial neural network (ANN) was employed to mitigate the influence of time delay, This ANN was trained using data from the El-Centro earthquake. The inputs of ANN are the seismic responses of the structure in the current step, and the ou...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: SN Applied Sciences
سال: 2019
ISSN: 2523-3963,2523-3971
DOI: 10.1007/s42452-019-0210-4