Active arc suppression device based on voltage?source convertor with consideration of line impedance in distribution networks
نویسندگان
چکیده
In the non-effectively grounding distribution system, residual current under single-line-to-ground (SLG) fault threatens safety of human being and power supply equipment. Active arc suppression device has been proved to be effective for SLG when line impedance is ignored. However, in practice, varies with location load flowing through brings about additional voltage drop, which increases not dealt by conventional methods. To achieve accurate existence impedance, neutral-to-ground reference full ground-fault compensation firstly derived a detection method then proposed. The pre-fault post-fault currents are used eliminate influence on drop. A dual-loop controller designed. prototype active was developed. results simulation experiment validate effectiveness proposed method.
منابع مشابه
Resilience Enhancement of Active Distribution Networks Via Mobile Energy Storage Systems and Protection Coordination Consideration
Owing to the portability and flexibility of mobile energy storage systems (MESSs), they seem to be a promising solution to improve the resilience of the distribution system (DS). So, this paper presents a rolling optimization mechanism for dispatching MESSs and other resources in microgrids in case of a natural disaster occurrence. The proposed mechanism aims to minimize the total system cost b...
متن کاملfault location in power distribution networks using matching algorithm
چکیده رساله/پایان نامه : تاکنون روشهای متعددی در ارتباط با مکان یابی خطا در شبکه انتقال ارائه شده است. استفاده مستقیم از این روشها در شبکه توزیع به دلایلی همچون وجود انشعابهای متعدد، غیر یکنواختی فیدرها (خطوط کابلی، خطوط هوایی، سطح مقطع متفاوت انشعاب ها و تنه اصلی فیدر)، نامتعادلی (عدم جابجا شدگی خطوط، بارهای تکفاز و سه فاز)، ثابت نبودن بار و اندازه گیری مقادیر ولتاژ و جریان فقط در ابتدای...
Evaluation and Calculation of Overhead Line Impedance in Distribution Networks
Abstract: The determination of the impedance for overhead lines is a critical step before the analysis of distribution feeder such as load flow and short circuit calculation can begin. Because distribution systems consist of single-phase, two-phase, and untransposed three-phase lines serving unbalanced loads, it is necessary to retain the identity of the self and mutual impedance terms of condu...
متن کاملqfd planning with cost consideration in fuzzy environment
در عصر حاضر که رقابت بین سازمان ها بسیار گسترش یافته است، مطالعه و طرحریزی سیستم های تولیدی و خدماتی به منظور بهینه سازی عملکرد آنها اجتناب ناپذیر می باشد. بخش عمده ای از رقابت پذیری سازمان ها نتیجه رضایتمندی مشتریان آنها است. میزان موفقیت سازمان های امروزی به تلاش آنها در جهت شناسایی خواسته ها و نیازهای مشتریان و ارضای این نیازها بستگی دارد. از طرفی کوتاه کردن زمان ارائه محصول/خدمات به مشتریان...
15 صفحه اولActive Distribution Networks Restoration after Extreme Events
After extreme events such as floods, thunderstorms, blizzards and hurricanes there will be devastating effects in the distribution networks which may cause a partial or complete blackout. Then, the major concern for the system operators is to restore the maximum critical loads as soon as possible by available generation units. In order to solve this problem, this paper provides a restoration s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Iet Power Electronics
سال: 2021
ISSN: ['1755-4535', '1755-4543']
DOI: https://doi.org/10.1049/pel2.12203