Active and reactive power control of grid?connected single?phase asymmetrical eleven?level inverter
نویسندگان
چکیده
In recent times, multilevel inverters (MLIs) have become very popular for commercial and industrial applications. Here, an eleven-level inverter its power flow control are presented. The presented topology has a lesser component count than other existing topologies, thus reducing the devices overall cost of inverter. This comprises six bidirectional switches, two DC sources, one four-quadrant switch, capacitors voltage divider circuit. conduction modes corresponding switching states shown in detail. Further, apparent under grid-connected operation is discussed, which provides simultaneous active reactive over injected into grid. Switching losses calculated 3 6 kVA grid at 0.8 factor lagging. obtained results show that total harmonic distortion (THD) output current 12.10% 0.23%, respectively, transfer conditions. real-time analysis also carried out conditions to validate control.
منابع مشابه
A Grid-Connected PV Inverter with Compensation of Load Active and Reactive Power Imbalance for Distribution Networks
Load balancing is an important issue in distributed systems. In addition, using distributed generation sources such as photovoltaic is increasing. Power electronic converters are main interfaces between the sources and the grid. In this paper, a method has been proposed to reduce the load imbalancing in distribution networks using PV Grid Interface Converter. Two DC/DC and DC/AC converters have...
متن کاملModel Predictive Control of a BCDFIG With Active and Reactive Power Control Capability for Grid-Connected Applications
Recently, Brushless Cascaded Doubly Fed Induction Generator (BCDFIG) has been considered as an attractive choice for grid-connected applications due to its high controllability and reliability. In this paper, a Finite Control Set Model Predictive Control (FCS-MPC) method with active and reactive power control capability in grid-connected mode is proposed for controlling the BCDFIG in a way that...
متن کاملActive Filter Control Method Based on Direct Power Control for Compensating Reactive Powers due to Unbalanced Voltages and Nonlinear Loads
Active filters have proven to be more effective than passive techniques to improve power quality and to solve harmonic and power factor problems due to nonlinear loads. This paper proposes a control scheme based on the instantaneous active and reactive power. The inverter of this active filter is a three-phase, two-level converter. Space vector technique is used as modulators and pattern genera...
متن کاملSliding-Mode-based Improved Direct Active and Reactive Power Control of Doubly Fed Induction Generator under Unbalanced Grid Voltage Condition
This paper proposes an improved direct active and reactive power control (DPC) strategy for a grid-connected doubly fed induction generator (DFIG) based wind-turbine system under unbalanced grid voltage condition. The method produces required rotor voltage references based on the sliding mode control (SMC) approach in stationary reference frame, without the requirement of synchronous coordinate...
متن کاملComparison Of Asymmetrical Cascaded Multilevel Inverter Control Techniques
This paper presents asymmetrical cascaded multilevel inverter (ACMLI) approach for high voltage and high power output applications. It is based on the cascade connection of the H-bridge inverter cells. Now ever by the supplies which are in GP with different ratios like 2,3,etc. The proposed configuration is shown for 27 level inverters with symmetrical step control, optimization angle control a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Iet Generation Transmission & Distribution
سال: 2022
ISSN: ['1751-8687', '1751-8695']
DOI: https://doi.org/10.1049/gtd2.12442