Acoustic Based Location of Corona Discharge in Oil-filled Transformer
نویسندگان
چکیده
منابع مشابه
Acoustic Spectroscopy of Magnetic Fluid Based on Transformer Oil
The structural changes in a magnetic fluid (formation of clusters) upon the effect of an external magnetic field were studied by acoustic spectroscopy. The properties of magnetic fluid dispersed in inhibited transformer oil ITO 100 have been studied by the analysis of changes in the acoustic wave absorption coefficient. The absorption coefficient of acoustic waves was measured as a function of ...
متن کاملDGA Interpretation of Oil Filled Transformer Condition Diagnosis
Copyright 2012 KIEEME. All rights reserved. This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. pISSN: 1229-7607 eISSN: 2092-7592 DOI: http://dx...
متن کاملRose-Window Instability of Oil Surfaces Exposed In Corona Discharge
We studied the Rose Window instability phenomenon on a layer of low conducting liquid (e.g. oil) that is exposed under corona discharge. Most of the current researches focus on deducting qualitative descriptions of this phenomenon in fluid mechanical aspect, but lacks experiments and the study of micro mechanism of the forming of cellular structure. In this thesis, a series of verification expe...
متن کاملOn-line Monitoring System Based on Principle of Electro-acoustic Monitoring for Transformer Partial Discharge
Partial discharge inside a transformer is mainly responsible for the insulation aging and damage of the transformer. However, partial discharge is usually accompanied by external signals like sound, light and electrical signals and detectable physical phenomena such as characteristical gas and dielectric loss. Therefore, it is of great significance to monitor online the external signals and phe...
متن کاملClassification of Acoustic Emission Based Partial Discharge in Oil Pressboard Insulation System Using Wavelet Analysis
Insulation used in transformer is mostly oil pressboard insulation. Insulation failure is one of the major causes of catastrophic failure of transformers. It is established that partial discharges (PD) cause insulation degradation and premature failure of insulation. Online monitoring of PDs can reduce the risk of catastrophic failure of transformers. There are different techniques of partial d...