Achievable noise performance of spectroscopic prototype DEPFET detectors
نویسندگان
چکیده
منابع مشابه
The DEPFET Sensor-Amplifier Structure: A Method to Beat 1/f Noise and Reach Sub-Electron Noise in Pixel Detectors
Depleted field effect transistors (DEPFET) are used to achieve very low noise signal charge readout with sub-electron measurement precision. This is accomplished by repeatedly reading an identical charge, thereby suppressing not only the white serial noise but also the usually constant 1/f noise. The repetitive non-destructive readout (RNDR) DEPFET is an ideal central element for an active pixe...
متن کاملThe Flat Fielding and Achievable Signal-to-Noise of the MAMA Detectors
The Space Telescope Imaging Spectrograph (STIS) was designed to achieve a signal-to-noise of at least 100:1 per resolution element. MAMA observations during Servicing Mission Orbital Verification (SMOV) confirm that this specification can be met. From analysis of a single spectrum of GD153, with counting statistics of ∼ 165 a S/N of ∼ 125 is achieved per spectral resolution element in the FUV o...
متن کاملPerformance Evaluation of Local Detectors in the Presence of Noise for Multi-Sensor Remote Sensing Image Matching
Automatic, efficient, accurate, and stable image matching is one of the most critical issues in remote sensing, photogrammetry, and machine vision. In recent decades, various algorithms have been proposed based on the feature-based framework, which concentrates on detecting and describing local features. Understanding the characteristics of different matching algorithms in various applications ...
متن کاملDevelopment of Prototype Pixellated PIN CdZnTe Detectors
We report initial results from the design and evaluation of two pixellated PIN Cadmium Zinc Telluride detectors and an ASIC-based readout system. The prototype imaging PIN detectors consist of 4 × 4 1.5 mm square indium anode contacts with 0.2 mm spacing and a solid cathode plane on 10 × 10 mm CdZnTe substrates of thickness 2 mm and 5 mm. The detector readout system, based on low noise preampli...
متن کاملAchievable accuracy in brain tumors by in vivo dosimetry with diode detectors
ABSTRACT Background: In vivo measurements of applied dose during radiotherapy treatment, is important to ensure accurate dose delivery to patients. Uncertainty in dose delivery should fall within ±5% of the prescribed dose as recommended by ICRU. Assessment of dose for radiotherapy applications performed with various types of detectors. In this study, semiconductor diodes were used which have s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Instrumentation
سال: 2018
ISSN: 1748-0221
DOI: 10.1088/1748-0221/13/12/p12001