Accurate time interval in repeated tonometry
نویسندگان
چکیده
منابع مشابه
Small bowel tonometry is more accurate than gastric tonometry in detecting gut ischemia.
Gastric tonometer PCO2 measurement may help identify gut ischemia in critically ill patients but is frequently associated with large measurement errors. We tested the hypothesis that small bowel tonometer PCO2 measurement yields more accurate information. In 10 anesthetized, mechanically ventilated pigs subject to progressive hemorrhage, we measured gut oxygen delivery and consumption. We also ...
متن کاملAccurate time interval measurement electronics for pulsed time of flight laser radar
A time-to-digital converter for pulsed time-offlight laser radar devices has been developed and six units have been constructed and tested thoroughly. The time interval between the start and stop pulses is digitized coarsely by counting the 100 MHz clock oscillator pulses. The +/-10 ns uncertainty is improved to +/-10 ps by means of an analogue interpolation method based on the discharge of a k...
متن کاملMalmquist productivity index in several time periods on interval data
The productivity change of a decision making unit (DMU) between two time periods can be evaluated by the Malmquist productivity index. In this study, we propose a method to compute the Malmquist productivity index in several time periods (from the first to the last periods) on interval data in data envelopment analysis (DEA). Then, the obtained Malmquist productivity index is compared with Malm...
متن کاملTonometry in corneal edema after cataract surgery: dynamic contour tonometry versus Goldmann applanation tonometry
INTRODUCTION Intraocular pressure (IOP) determination using dynamic contour tonometry (DCT) has been considered to be independent of central corneal thickness (CCT), while Goldmann applanation tonometry (GAT) is known to be influenced by various corneal properties. In this study, IOP was measured before and 1 day after cataract surgery using GAT and DCT to investigate the possible effects of co...
متن کاملEvaluation of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in keratoconus
PURPOSE To compare the intraocular pressure (IOP) measurements obtained with the rebound tonometry (RT), dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in keratoconic corneas and to investigate the effects of central corneal thickness (CCT) and corneal radius of curvature (CR) on IOP measurements. METHODS Sixty-three eyes of 63 keratoconus patients were enrolled in t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Ophthalmologica Scandinavica
سال: 1998
ISSN: 1395-3907,1600-0420
DOI: 10.1034/j.1600-0420.1998.760518.x