Accurate Superimposed Component Estimation for Improved Relay Performance During Power Swing
نویسندگان
چکیده
There is continuous variation in amplitude, phase, and frequency of voltage current signals during power swing a system. Such makes the memorized prefault data less accurate to be used as nonfault component while computing superimposed quantity for protection decisions swing. In this article, signal characteristics are analyzed technique proposed obtain correct components computation. The accuracy method estimating observed different conditions simulated 39-bus New England system field data. relay performance improvement also provided applying directional relaying, fault type classification, location applications faults Comparative assessment reveals superiority improving computed
منابع مشابه
Improved Symmetrical Fault Detection Scheme during Power Swing
Relays may not perform as intended occasionally due to many complex reasons, which may result in relay misoperation. This paper provides a fast detection scheme for symmetrical fault during power swing based on travelling wave theory and wavelet transform. The implementation of the proposed method is discussed in detail, which covers implementation framework, data requirements, selection of mot...
متن کاملAccurate Relay Selection for Improved Multipath Throughput in Internet Overlays
Distributed applications deployed over the Internet, such as in grids, clouds, or P2P networks, crucially depend on the speed of their Internet connections. A common solution is to exploit underlying network parallelism via multipath routing within an application-level overlay network. Accurately selecting appropriate relay hosts within an overlay, however, remains a challenging problem, freque...
متن کاملAccurate logic - level power estimation
sizable errors for gates with highly loaded inputs and lightly loaded outputs [3]. The connection matrix can be used to detect conditions for which there is a transient open path between Vdd and Vss. On every input pattern transition , we check if any node that was connected to Vdd in the old input conguration is connected to Vss in the new one or viceversa. If this condition is veried, short c...
متن کاملSuperimposed Training-Based Joint CFO and Channel Estimation for CP-OFDM Modulated Two-Way Relay Networks
Joint carrier frequency offset (CFO) and channel estimation is considered for two-way relay networks (TWRNs). Existing estimators provide only the convolved channel parameters and themixed CFO values. In contrast, estimators using a superimposed training strategy are developed for the individual frequency and channel parameters. Depending on the number of pilots, three different estimators are ...
متن کاملAn Accurate Estimation of Power Using Verilog
Power has become major design concern for complex VLSI circuits today. Designer needs tool(s) that accurately estimate the power dissipation in a given design. We need two categories of tools that are useful for this purpose. One is power optimization tools and, second is an analysis tool for estimating the power consumption in an existing netlist. This approach addresses the second issue by em...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Systems Journal
سال: 2022
ISSN: ['1932-8184', '1937-9234', '2373-7816']
DOI: https://doi.org/10.1109/jsyst.2021.3138758