Multichannel processing for airborne gamma-ray spectrometry
The conventional approach to the processing of airborne gamma-ray spectrometric data is to first sum the observed spectra over three relatively broad energy windows. These three window count rates are then processed to obtain estimates of the potassium (K), uranium (U), and thorium (Th) elemental abundances. However, multichannel spectra contain additional information on the concentrations of K...
متن کاملEvaluating the Reliability of an Accurate Performance in Tray Columns Using Gamma Ray Scanning Technique
The nondestructive techniques are applied to identify important data from the internal process of distillation towers, process towers, pressure vessels and etc. In recent, the gamma-ray scanning techniques as diagnostic tools for scanning of tray columns, packed columns, storage tanks, level measurement and density measurement of containing materials has been used widely. This paper has tried t...
متن کاملCircular Mean Filtering For Textures Noise Reduction
In this paper, a special preprocessing operations (filter) is proposed to decrease the effects of noise of textures. This filter using average of circular neighbor points (Cmean) to reduce noise effect. Comparing this filter with other average filters such as square mean filter and square median filter indicates that it provides more noise reduction and increases the classification accuracy...
متن کاملIMPLEMENTATION OF EXTENDED KALMAN FILTER TO REDUCE NON CYCLO-STATIONARY NOISE IN AERIAL GAMMA RAY SURVEY
Gamma-ray detection has an important role in the enhancement the nuclear safety and provides a proper environment for applications of nuclear radiation. To reduce the risk of exposure, aerial gamma survey is commonly used as an advantage of the distance between the detection system and the radiation sources. One of the most important issues in aerial gamma survey is the detection noise. Various...
متن کاملMonte Carlo Simulation for Airborne Gamma Ray Spectrometry
The aerial measuring terrestrial gamma radiation from airborne platforms is a useful method for characterizing the radiation levels over large areas. Because of the advantage of Monte Carlo method, it is very suitable for simulation of gamma ray transport and interaction with media (soil, air, aircraft and detector), which offer alternative means of estimating detector response and calibration ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: ASEG Extended Abstracts
سال: 2003
ISSN: 2202-0586
DOI: 10.1071/aseg2003ab110