Accuracy of Schiotz Tonometry in Measuring the Intraocular Pressure After Corneal Refractive Surgery
نویسندگان
چکیده
منابع مشابه
Pressure phosphene tonometry versus Goldmann applanation tonometry for measuring intraocular pressure before and after LASIK.
PURPOSE To compare pressure phosphene tonometry with Goldmann applanation tonometry for measuring intraocular pressure (IOP) before and after LASIK. METHODS Forty-three (18 men and 25 women) consecutive healthy patients underwent complete pre- and postoperative LASIK ophthalmologic assessments including manifest and cycloplegic refraction, keratometry, and central corneal thickness. Three rep...
متن کاملIntraocular Lens Power Calculation after Corneal Refractive Surgery
PURPOSE To determine the accuracy of a method of calculating intraocular lens (IOL) power after corneal refractive surgery. SETTING Department of Ophthalmology, Hospital de Gipuzkoa, San Sebastián, Spain. METHODS The SRK/T formula was modified to use the pre refractive surgery K-value (Kpre) for the effective lens position (ELP) calculation and the post refractive surgery K-value (Kpost) fo...
متن کاملIntraocular lens power calculatio n after corneal refractive surgery
Current Opinion in Ophthalmology 2008, 19:357–362 Purpose of review Corneal refractive procedures have become increasingly popular over the past decade allowing patients to have excellent uncorrected visual acuity and spectacle independence. As these individuals mature, many will eventually undergo cataract surgery. With the advances in modern cataract surgery and lens implant technology, parti...
متن کاملComparison of Intraocular Pressure before and after Laser In Situ Keratomileusis Refractive Surgery Measured with Perkins Tonometry, Noncontact Tonometry, and Transpalpebral Tonometry
Purpose. To compare the intraocular pressure (IOP) before and after Laser In Situ Keratomileusis (LASIK), measured by Diaton, Perkins, and noncontact air pulse tonometers. Methods. Fifty-seven patients with a mean age of 34.88 were scheduled for myopia LASIK treatment. Spherical equivalent refraction (SER), corneal curvature (K), and central corneal thickness (CCT) and superior corneal thicknes...
متن کاملTonometry in corneal edema after cataract surgery: dynamic contour tonometry versus Goldmann applanation tonometry
INTRODUCTION Intraocular pressure (IOP) determination using dynamic contour tonometry (DCT) has been considered to be independent of central corneal thickness (CCT), while Goldmann applanation tonometry (GAT) is known to be influenced by various corneal properties. In this study, IOP was measured before and 1 day after cataract surgery using GAT and DCT to investigate the possible effects of co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Optometry
سال: 2008
ISSN: 1888-4296
DOI: 10.3921/joptom.2008.59