Accuracy of methods to measure femoral head penetration within metal-backed acetabular components

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Finite Element Analysis Stress Distribution Acetabular Cup Biomaterial FINITE ELEMENT ANALYSIS OF PERI-ACETABULAR STRESS OF CEMENTED, METAL-BACKED, AND POROUS TANTALUM BACKED ACETABULAR COMPONENTS

Introduction: In contemporary THA there are two broad approaches to acetabular cup design and materials. One is an all-polyethylene design with polymethylmethacrylate (PMMA) cement. PMMA possesses a modulus of elasticity of about 2 GPa, which is between that of trabecular and subchondral bone. The second more popular approach, especially for active, younger patients, is the porous metal-backed ...

متن کامل

Measurement of femoral head penetration in polyethylene using a 3-dimensional CT-scan technique

BACKGROUND Current techniques for measuring in vivo polyethylene wear suffer from a range of problems, resulting in an unacceptable lack of repeatability and/or insufficient accuracy when they are used to measure the low wear rates associated with new, highly crosslinked polyethylene. We describe an improved CT method for measurement of 3D femoral head penetration in PE acetabular cups that has...

متن کامل

Metal-backed acetabular components with conventional polyethylene: a review of 9113 primary components with a follow-up of 20 years.

The Norwegian Arthroplasty Register has shown that several designs of uncemented femoral stems give good or excellent survivorship. The overall findings for uncemented total hip replacement however, have been disappointing because of poor results with the use of metal-backed acetabular components. In this study, we exclusively investigated the medium-to long-term performance of primary uncement...

متن کامل

The use of stereophotogrammetry to measure acetabular and femoral anteversion.

Stereoradiography with a base shift of the source of illumination was used to produce pairs of radiographs to be measured by stereophotogrammetric techniques. The direction of shift was parallel with the longitudinal axis of the body, so that each radiograph in the stereopair could be used for other clinical purposes. A base shift of 10 centimetres with a distance of 100 centimetres between the...

متن کامل

Polyethylene wear in cemented metal-backed acetabular cups.

We examined radiographic polyethylene wear in 233 cemented total hip arthroplasties (201 patients) with either a metal-backed or a non-metal-backed acetabular cup. All patients had identical cemented one-piece titanium femoral stems with a femoral head diameter of 28 mm. The mean linear wear rate was 0.11 mm/yr in metal-backed sockets and 0.08 mm/yr in non-metal-backed sockets (p = 0.0002). The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Orthopaedic Research

سال: 2016

ISSN: 0736-0266

DOI: 10.1002/jor.23356