Accuracy of mechanical torque-limiting gauges for mini-screw placement
نویسندگان
چکیده
منابع مشابه
Accuracy Assessment of Freehand Pedicular Screw Placement
Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...
متن کاملevaluation of the accuracy and related factors of the mechanical torque-limiting device for dental implants.
accurate delivery of torque to implant screws is critical to generate ideal preload in the screw joint and to offer protection against screw loosening. mechanical torque-limiting devices (mtlds) are available for this reason. in this study, the accuracy of one type of friction-style and two types of spring-style mtlds at baseline, following fatigue conditions and sterilization processes were de...
متن کاملEvaluation of the Accuracy and Related Factors of the Mechanical Torque-Limiting Device for Dental Implants
OBJECTIVE Accurate delivery of torque to implant screws is critical to generate ideal preload in the screw joint and to offer protection against screw loosening. Mechanical torque-limiting devices (MTLDs) are available for this reason. In this study, the accuracy of one type of friction-style and two types of spring-style MTLDs at baseline, following fatigue conditions and sterilization process...
متن کاملAccuracy of mechanical torque-limiting devices for dental implants after clinical service.
STATEMENT OF PROBLEM Limited information is available regarding the accuracy of mechanical torque-limiting devices (MTLDs) after their clinical use. PURPOSE The purpose of this study was to determine the accuracy of 2 types of MTLDs (friction-style and spring-style) after clinical use. MATERIAL AND METHODS Twenty-seven MTLDs in clinical service at The Ohio State University College of Dentis...
متن کاملthe effect of aging on the accuracy of spring-style mechanical torque limiting devices for dental implants
objective: recently, a wide variation has been reported in delivery of the target torque by spring-style mechanical torque limiting devices (mtlds) but the effect of aging on their accuracy has not been independently evaluated. the purpose of this study was to determine the effect of aging on the accuracy of spring-style mtlds. methods: in this in-vitro experimental study, 15 new spring-style m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Clinical Oral Implants Research
سال: 2010
ISSN: 0905-7161,1600-0501
DOI: 10.1111/j.1600-0501.2010.01927.x