Purpose. This study aims to compare the accuracy of intraocular lens power calculation formulas in eyes with long axial lengths from Chinese patients subjected to cataract surgery. Methods. A total of 148 eyes with an axial length of >26 mm from 148 patients who underwent phacoemulsification with intraocular lens implantation were included. The Haigis, Hoffer Q, Holladay 1, and SRK/T formulas w...
متن کاملUsefulness of Implantation of Diffractive Multifocal Intraocular Lens in Eyes with Long Axial Lengths
Purpose. This study retrospectively analyzed the postoperative visual functions of myopic eyes implanted with multifocal intraocular lens (IOL) to evaluate the efficacy of multifocal IOL in highly myopic eyes. Methods. We studied 61 patients (96 eyes) who were implanted with multifocal IOL ZMA00 or ZMB00 (Abbott Medical Optics). The patients were stratified into two groups by axial length: 26 m...
متن کاملAccuracy of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes.
Purpose. To evaluate and compare the accuracy of different intraocular lens (IOL) power calculation formulas for eyes with an axial length (AL) greater than 26.00 mm. Methods. This study reviewed 407 eyes of 219 patients with AL longer than 26.0 mm. The refractive prediction errors of IOL power calculation formulas (SRK/T, Haigis, Holladay, Hoffer Q, and Barrett Universal II) using User Group f...
متن کاملIntraocular Lens Power Calculation Using IOLMaster and Various Formulas in Short Eyes
PURPOSE To evaluate the predictability of intraocular lens (IOL) power calculations using the IOLMaster and four different IOL power calculation formulas (Haigis, Hoffer Q, SRK II, and SRK/T) for cataract surgery in eyes with a short axial length (AL). METHODS The present study was a retrospective comparative analysis which included 25 eyes with an AL shorter than 22.0 mm that underwent uneve...
متن کاملAccuracy of Intraocular Lens Power Calculation Formulas in Primary Angle Closure Glaucoma
PURPOSE To compare the accuracy of intraocular lens (IOL) power calculation formulas in eyes with primary angle closure glaucoma (ACG). METHODS This retrospective study compared the refractive outcomes of 63 eyes with primary ACG with the results of 93 eyes with normal open angles undergoing uneventful cataract surgery. Anterior segment biometry including anterior chamber depth, axial length,...