Accuracy of Intraocular Lens Power Calculations Based on Total and Standard Keratometry
نویسندگان
چکیده
منابع مشابه
Effect of corneal aberrations on intraocular lens power calculations.
PURPOSE To use ray tracing to determine the influence of corneal aberrations on the prediction of the optimum intraocular lens (IOL) power for implantation in normal eyes and eyes with previous laser in situ keratomileusis (LASIK). SETTING Hospital Universitario Virgen de la Arrixaca, Murcia, Spain. DESIGN Case series. METHODS The optimum IOL power was calculated by ray tracing using a pa...
متن کاملAccuracy of intraocular lens power calculations using the Zeiss IOL master. A prospective study.
PURPOSE Partial Coherence Interferometry (PCI) is a fast, noncontact method to calculate lens implant power for cataract surgery. It has been reported as a potentially more accurate method than ultrasound biometry. Prospective study of the refractive outcomes of a consecutive series of patients undergoing phacoemulsification surgery with preoperative biometry by both ultrasound A-scan and PCI. ...
متن کاملAccuracy of formulae for secondary intraocular lens power calculations in pediatric aphakia
PURPOSE To compare the accuracy of axial length vergence formulas versus refractive vergence formulas for secondary intraocular lens (IOL) implantation in pediatric aphakia. METHODS This retrospective comparative study, evaluated 31 eyes of 31 patients aged ≤3.5 years, who had undergone secondary IOL implantation. The median absolute error (MedAE) was compared between axial length vergence fo...
متن کاملapplication of upfc based on svpwm for power quality improvement
در سالهای اخیر،اختلالات کیفیت توان مهمترین موضوع می باشد که محققان زیادی را برای پیدا کردن راه حلی برای حل آن علاقه مند ساخته است.امروزه کیفیت توان در سیستم قدرت برای مراکز صنعتی،تجاری وکاربردهای بیمارستانی مسئله مهمی می باشد.مشکل ولتاژمثل شرایط افت ولتاژواضافه جریان ناشی از اتصال کوتاه مدار یا وقوع خطا در سیستم بیشتر مورد توجه می باشد. برای مطالعه افت ولتاژ واضافه جریان،محققان زیادی کار کرده ...
15 صفحه اولIOLMaster keratometry for the calculation of toric intraocular lens power and orientation
In the implantation of intraocular lenses (IOL) stringent requirements are made on achieving the refractive target. This necessitates the exact determination of the basic data needed for IOL power calculation – both the axial length and, in particular, the corneal power – and additionally the cylinder power and its axis in the case of a toric lens. This gives rise to the question, especially fo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Korean Ophthalmological Society
سال: 2020
ISSN: 0378-6471,2092-9374
DOI: 10.3341/jkos.2020.61.11.1265