Accuracy of Gypsum Casts after Different Impression Techniques and Double Pouring
نویسندگان
چکیده
منابع مشابه
Accuracy of Gypsum Casts after Different Impression Techniques and Double Pouring
This study evaluated the accuracy of gypsum casts after different impression techniques and double pouring. Ten patients were selected and for each one it was obtained 5 partial putty/wash impressions with vinyl polysiloxane (VPS) material from teeth #13 to #16 with partial metal stock trays. The following techniques were performed: (1) one-step; two-step relief with: (2) PVC film; (3) slow-spe...
متن کاملeffect of different impression materials and techniques on the dimensional accuracy of implant defi nitive casts
background: different factors such as impression techniques and materials can affect the passive fi t between the superstructure and implant. the aim of this study was to determine the effect of different impression materials and techniques on the dimensional accuracy of implant defi nitive casts. materials and methods: four internal hex implants (biohorizons ø4 mm) were placed on a metal maxil...
متن کاملThe Effects of Disinfectants on Dimensional Accuracy and Surface Quality of Impression Materials and Gypsum Casts
BACKGROUND The study aimed to evaluating the effect of disinfecting impression materials on the dimensional accuracy and surface quality of the resulting casts. METHODS Impressions of a steel die constructed according to ANSI/ADA specification No.18 were made with each of alginate, addition cured silicone, condensation cured silicone and zinc oxide eugenol paste, and disinfected consequently ...
متن کاملAccuracy of stone casts obtained by different impression materials.
Several impression materials are available in the Brazilian marketplace to be used in oral rehabilitation. The aim of this study was to compare the accuracy of different impression materials used for fixed partial dentures following the manufacturers' instructions. A master model representing a partially edentulous mandibular right hemi-arch segment whose teeth were prepared to receive full cro...
متن کاملEffect of different impression materials and techniques on the dimensional accuracy of implant definitive casts
BACKGROUND Different factors such as impression techniques and materials can affect the passive fit between the superstructure and implant. The aim of this study was to determine the effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts. MATERIALS AND METHODS Four internal hex implants (Biohorizons Ø4 mm) were placed on a metal maxilla...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: PLOS ONE
سال: 2016
ISSN: 1932-6203
DOI: 10.1371/journal.pone.0164825