Accuracy of Consumer Grade Bioelectrical Impedance Analysis Devices Compared to Air Displacement Plethysmography

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Body fat measurement by bioelectrical impedance and air displacement plethysmography: a cross-validation study to design bioelectrical impedance equations in Mexican adults

BACKGROUND The study of body composition in specific populations by techniques such as bio-impedance analysis (BIA) requires validation based on standard reference methods. The aim of this study was to develop and cross-validate a predictive equation for bioelectrical impedance using air displacement plethysmography (ADP) as standard method to measure body composition in Mexican adult men and w...

متن کامل

Whole body air displacement plethysmography compared with hydrodensitometry for body composition analysis.

AIMS To assess the acceptability and feasibility of whole body air displacement plethysmography in children and to determine its precision and agreement with hydrodensitometry, an appropriate reference method. METHODS Age specific two component model equations were used to predict fat mass from body density in 22 children aged 8-12 years and in 10 adults for comparison of methods. Precision f...

متن کامل

A Comparison of Body Composition Across Two Phases of the Menstrual Cycle Utilizing Dual-Energy X-Ray Absorptiometry, Air Displacement Plethysmography, and Bioelectrical Impedance Analysis

The purpose of this investigation was to utilize several different technologies to compare body composition results across two phases of the menstrual cycle, and to investigate whether being on hormonal birth control or not has any effect on results. The secondary purpose was to determine if body satisfaction or perception of fluid retention differed across phases or between groups. A total of ...

متن کامل

Comparison of air-displacement plethysmography with hydrostatic weighing and bioelectrical impedance analysis for the assessment of body composition in healthy adults.

BACKGROUND Over the past decade, considerable attention has been paid to accurately measuring body composition in diverse populations. Recently, the use of air-displacement plethysmography (AP) was proposed as an accurate, comfortable, and accessible method of body-composition analysis. OBJECTIVE The purpose of this study was to compare measurements of percentage body fat (%BF) by AP and 2 ot...

متن کامل

Accuracy of wholebody fat quantification with MRI: A comparison to Air-Displacement Plethysmography

Introduction Besides the total amount of adipose tissue, its distribution has recently been recognized as an important factor in the pathogenesis of metabolic diseases like diabetes mellitus [1]. MRI is capable for space-resolved imaging of fat distributions in the human body and various segmentation techniques have been introduced, which are based on MRI data [2,3]. In these studies, fat relat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Medicine & Science in Sports & Exercise

سال: 2007

ISSN: 0195-9131

DOI: 10.1249/01.mss.0000274464.50186.ed