Accumulated oxygen deficit on a continuous incremental exercise test
نویسندگان
چکیده
منابع مشابه
Association between anaerobic components of the maximal accumulated oxygen deficit and 30-second Wingate test
The purpose of this study was to analyze the relationship between the anaerobic components of the maximal accumulated oxygen deficit (MAOD) and of the 30-second Wingate anaerobic test (30-WAnT). Nine male physical education students performed: a) a maximal incremental exercise test; b) a supramaximal constant workload test to determine the anaerobic components of the MAOD; and c) a 30-WAnT to m...
متن کاملBlood lipid responses after continuous and accumulated aerobic exercise.
The purpose of this study was to compare blood lipid responses to continuous versus accumulated exercise. Nine participants completed the following conditions on separate occasions by treadmill walking/jogging at 70% of VO2max: 1) one 500-kcal session and 2) three 167 kcal sessions. Total cholesterol (TC), high-density lipoprotein cholesterol (HDL-C), and triglycerides (TG) concentrations were ...
متن کاملEnergy system contributions during incremental exercise test.
The main purpose of this study was to determine the relative contributions of the aerobic and glycolytic systems during an incremental exercise test (IET). Ten male recreational long-distance runners performed an IET consisting of three-minute incremental stages on a treadmill. The fractions of the contributions of the aerobic and glycolytic systems were calculated for each stage based on the o...
متن کاملThe maximal accumulated oxygen deficit method: a valid and reliable measure of anaerobic capacity?
The maximal accumulated oxygen deficit (MAOD) method has been extensively, but unfortunately not very methodically, used; the procedure used to determine the MAOD varies considerably. Therefore, this review evaluates the effect of different numbers and durations of submaximal exercise bouts on the linear power output (PO)-oxygen uptake ((.)VO2) relationship and thus the MAOD. Changing the numbe...
متن کاملEstimation of accumulated oxygen deficit from accumulated blood lactate concentration during supramaximal running in middle-distance runners
The maximal accumulated oxygen deficit (MAOD), which is the gold standard for anaerobic energy metabolism capacity, requires multiple tests for evaluation that impose a heavy load on subjects. The maximal accumulated blood lactate (ΔbLa) concentration is also a measure of anaerobic energy metabolism capacity, and is related to the accumulated oxygen deficit (AOD). Thus, AOD has been estimated b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The FASEB Journal
سال: 2006
ISSN: 0892-6638,1530-6860
DOI: 10.1096/fasebj.20.4.a810-d