Accommodative intraocular lens concepts

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Accommodative Performance of a New Accommodative Intraocular Lens.

PURPOSE To compare objective and subjective accommodation and visual acuities with a new accommodative intraocular lens (IOL) (Lumina; AkkoLens Clinical BV, Rijswijk, The Netherlands) with a monofocal IOL and young phakic eyes. METHODS In this prospective, randomized controlled clinical investigation, patients aged 51 to 85 years with symptomatic cataract were enrolled in the study. A total o...

متن کامل

Potential of the 1 CU accommodative intraocular lens.

AIM To assess the accommodative power of a new foldable monofocal intraocular lens. METHOD A prospective randomised non-masked clinical interventional study. The study included 40 patients attending the hospital for cataract surgery and who were randomly distributed into a study group receiving a new foldable monofocal intraocular lens with flexible haptics, and a control group receiving a st...

متن کامل

Mechanism of action of the tetraflex accommodative intraocular lens.

PURPOSE To investigate the mechanism of action of the Tetraflex (Lenstec Kellen KH-3500) accommodative intraocular lens (IOL). METHODS Thirteen eyes of eight patients implanted with the Tetraflex accommodating IOL for at least 2 years underwent assessment of their objective amplitude-of-accommodation by autorefraction, anterior chamber depth and pupil size with optical coherence tomography, a...

متن کامل

Implantation of a new accommodative posterior chamber intraocular lens.

PURPOSE A new, potentially accommodative posterior chamber lens (PCIOL) was designed based on principles elaborated by Hanna using finite element computer simulation methods. We report 3-month postoperative results in patients. METHODS In a prospective study, 12 eyes of 12 patients (age 45 to 87 yr) underwent phacoemulsification for cataracts and PCIOL implantation. The PCIOL, 1 CU, has hapti...

متن کامل

Objective accommodative amplitude and dynamics with the 1CU accommodative intraocular lens.

PURPOSE To compare the objective accommodative amplitude and dynamics of eyes implanted with the one-compartment-unit (1CU; HumanOptics AG, Erlangen, Germany) accommodative intraocular lenses (IOLs) with that measured subjectively. METHODS Twenty eyes with a 1CU accommodative IOL implanted were refracted and distance and near acuity measured with a logMAR (logarithm of the minimum angle of re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Acta Ophthalmologica

سال: 2019

ISSN: 1755-375X,1755-3768

DOI: 10.1111/j.1755-3768.2019.8050