Acceleration feedback control of human-induced floor vibrations
نویسندگان
چکیده
منابع مشابه
Impedance Modeling for Prediction of Train Induced Floor Vibrations
Laboratory and manufacturing facilities are frequently located in areas that experience high-frequency (greater than 30 Hz) environmental vibration. Such vibrations are a concern for the proper functioning of sensitive laboratory devices, precision manufacturing equipment as well as human comfort. A simple method to accurately predict the magnitude of high-frequency floor vibrations would allow...
متن کاملMitigation of Train-Induced Floor Vibrations in Multi-Story Buildings Using a Blocking Floor
A new method is developed for reducing train–induced floor vibrations in buildings. Vibration transmitted through building columns to the upper floors can be mitigated by considerably increasing the thickness of a lower floor, which is named the “blocking floor”. This can be a desirable and inexpensive solution for vibration mitigation. The work presented by this paper shows the ability of an i...
متن کاملContact transition control via joint acceleration feedback
Stable and controllable transition from free motion to constrained motion is of central importance for robots in contact with environment in many applications. In this paper, a joint acceleration feedback control of high bandwidth is employed to damp oscillations during the contact transition when the approaching speed does not vanish. In this control scheme, a classical integral force controll...
متن کاملNonlinear output-feedback control of torsional vibrations in drilling systems
1Department of Mechanical Engineering, Eindhoven University of Technology, 5600 MB, Eindhoven, The Netherlands 2Department of Civil, Environmental & Geo-Engineering, University of Minnesota, Minneapolis, USA 3Delft Center for Systems and Control, Delft University of Technology, Delft, The Netherlands 4Well Engineering Design, Nederlandse Aardolie Maatschappij B.V. (NAM), The Netherlands 5Wells ...
متن کاملApplication of Tuned Mass Dampers To Control Vibrations of Composite Floor Systems
Although the incidence of floor vibration problems appears to be on the rise, the use of mechanical damping devices to control vibrations is limited. In a recent survey of vibration control methods, Murray reports that passive-mechanical damping methods, including viscous damping, visco-elastic damping, and tuned-mass dampers, have often gone untried outside the laboratory or have had marginal ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Engineering Structures
سال: 2010
ISSN: 0141-0296
DOI: 10.1016/j.engstruct.2009.09.003