AC susceptibility measurements on ceramic YBa2Cu3O7.ysuperconductor in the GPa region

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ac susceptibility studies of the weak itinerant ferromagnet SrRuO3 under high pressure to 34 GPa

The dependence of the Curie temperature TCurie on nearly hydrostatic pressure has been determined to 17.2 GPa for the weak itinerant ferromagnet SrRuO3 in both polycrystalline and single-crystalline forms. TCurie is found to decrease under pressure from 162 to 42.7 K at 17.2 GPa in nearly linear fashion at the rate dTCurie /dP −6.8 K/GPa. No superconductivity was found above 4 K in the pressure...

متن کامل

AC susceptibility and ESR measurements on the Ag : Mn spin glass

2014 We present measurements between 1.2 and 4.2 K, of the AC susceptibility from 93 Hz to 109 kHz, and of the ESR at 1.6 and 9.2 GHz on dilute Ag : Mn spin glasses around TG. Within experimental error, the AC glass temperature is independent of the measuring frequency. The shift of the resonance line can be related to the applied static field but the temperature for a linewidth minimum is the ...

متن کامل

the impact of e-readiness on ec success in public sector in iran the impact of e-readiness on ec success in public sector in iran

acknowledge the importance of e-commerce to their countries and to survival of their businesses and in creating and encouraging an atmosphere for the wide adoption and success of e-commerce in the long term. the investment for implementing e-commerce in the public sector is one of the areas which is focused in government‘s action plan for cross-disciplinary it development and e-readiness in go...

AC Electrophoresis; Deposition of Ceramic Nanaoparticles on In-plane Electrodes at Low Frequencies (RESEARCH NOTE)

Deposition of ceramic nanoparticles (dispersed in a non-aqueous suspension) on in-plane electrodes and under the influence of AC electric fields in the frequency range of 0.01 Hz - 10 kHz is investigated. Analysis of the particle response to the applied field is a difficult task due to the mutual effect of electric- and hydrodynamic force which are present in the system. In this work, however, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Physics: Conference Series

سال: 2009

ISSN: 1742-6588,1742-6596

DOI: 10.1088/1742-6596/150/5/052271