AC Interference on Gas Pipeline due to Phase to Ground Faults in Overhead Transmission Line
نویسندگان
چکیده
منابع مشابه
Discussion of Converting a Double-Circuit AC Overhead Line to an AC/DC Hybrid Line with Regard to Audible Noise
That the large-scale integration of new renewables requires a substantial increase in transmission capacity seems to be an undoubted fact today. As new rights-of-way for transmission lines are increasingly difficult to obtain, alternatives are discussed to increase transmission capacity within the existing rights-of-way. One possibility to do so is the conversion of existing AC lines to DC. In ...
متن کاملElectromagnetic Field Due to Lightning Strikes to Mountainous Ground
The produced electric and magnetic fields due to lightning strikes to mountainous ground are determined in this paper. For the sake of simplicity a cone-shaped ground with finite conductivity is assumed to represent a natural nonflat ground. By this assumption, we deal with an axillary symmetrical structure so we use the cylindrical 2D-FDTD to save the simulation memory and time, dramatically. ...
متن کاملthe role of russia in transmission of energy from central asia and caucuses to european union
پس ازفروپاشی شوروی،رشد منابع نفت و گاز، آسیای میانه و قفقاز را در یک بازی ژئوپلتیکی انرژی قرار داده است. با در نظر گرفتن این منابع هیدروکربنی، این منطقه به یک میدانجنگ و رقابت تجاری برای بازی های ژئوپلتیکی قدرت های بزرگ جهانی تبدیل شده است. روسیه منطقه را به عنوان حیات خلوت خود تلقی نموده و علاقمند به حفظ حضورش می باشد تا همانند گذشته گاز طبیعی را به وسیله خط لوله مرکزی دریافت و به عنوان یک واس...
15 صفحه اولUsing of Dynamic Voltage Restorer (DVR) to Mitigate Sag & Swell Voltage during Single Line to Ground & Three- Phase Faults
متن کامل
Pole-to-Ground Fault Analysis and Fast Protection Scheme for HVDC Based on Overhead Transmission Lines
Flexible direct current (DC) transmission network technology is an effective method for large capacity clean energy access to power grids, but the DC short-circuit fault detection for it is a difficult problem. In this paper, the pole-to-ground fault transient characteristics in a multi-terminal DC power grid, based on overhead transmission lines and DC circuit breakers, are analyzed firstly. T...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Electrical and Computer Engineering (IJECE)
سال: 2016
ISSN: 2088-8708,2088-8708