Absorptive stripping voltammetry for cannabis detection
نویسندگان
چکیده
منابع مشابه
Absorptive stripping voltammetry for cannabis detection
BACKGROUND Given that Δ(9)-tetrahydrocannabinol, the active constituent of cannabis, has been shown to greatly reduce driving ability, thus being linked to many drug driving accidents, its reliable detection is of great importance. RESULTS An optimised carbon paste electrode, fabricated from graphite powder and mineral oil, is utilised for the sensitive detection of Δ(9)-tetrahydrocannabinol ...
متن کاملAptasensors Based on Stripping Voltammetry
Aptasensors based on stripping voltammetry exhibit several advantages, such as high sensitivity and multi-target detection from stripping voltammetric technology, and high selectivity from the specific binding of apamers with targets. This review comprehensively discusses the recent accomplishments in signal amplification strategies based on nanomaterials, such as metal nanoparticles, semicondu...
متن کاملDetermination of Aminophylline by Cathodic Stripping Voltammetry
Aminophylline is determined by cathodic stripping voltammetry (CSV) in BR buffer, pH 7.5 at a hanging mercury drop electrode. The detection limit was 3x10 M after 60 s accumulation at -0.60 V versus Ag/AgCl reference electrode. The linear range demonstrated up to 5x10 M using CSV. The interference caused by some purine derivatives, anions and some metal cations on the peak current was studied. ...
متن کاملHeavy Metal Analysis by Anodic Stripping Voltammetry
Let’s say that you wanted to determine the heavy metal identities and concentrations in sediment and suspended solid samples obtained from present day Lake Nakuru. What technique would you use for this determination? You could use Atomic Absorption Spectroscopy (AAS) as was done in the article (Nelson 1998), but another technique, which is particularly good at detecting metals at the ppb level ...
متن کاملDetermination of chitosan by cathodic stripping voltammetry.
A sensitive method for the determination of chitosan (CTS) by cathodic stripping voltammetry is presented. The method exploits a pair of oxidation-reduction peaks of CTS at -0.62 V (vs. SCE) and -0.54 V (vs. SCE), and an enhancement of the peak current of CTS observed in a 0.05 mol l(-1) potassium hydrogenphthalate buffer solution (pH 2.5). The peak current is linear with the concentration of C...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Chemistry Central Journal
سال: 2015
ISSN: 1752-153X
DOI: 10.1186/s13065-015-0117-0