Absolute salinity determination by oscillation-type densimetry and refractometry

نویسندگان

چکیده

The determination of salinity values from SI traceable densimetry and refractometry measurement results enable traceability the former. In this work, a short study metrological compatibility determinations via these two methods for sodium chloride in ultrapure water solutions different standard seawaters (OSIL ERM) solutions, [35.0; 215.0] g kg −1 interval, is presented. It evidenced referred interval. largest enabled to test matrix effect upon concluded preferable use technique, when occurring.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of partial specific volume and absolute concentration by densimetry.

The apparent partial specific volume, phi, of a protein (or other macromolecule) and the absolute concentration, c, can be determined from the densimetry of solutions and diffusates in 1H2O , 2H2O and 1H2O/2H2O mixtures if the ratios of concentrations (relative concentrations) are known. The densimetry method allows a non-destructive check on total macromolecule concentrations without prior kno...

متن کامل

Determination of anaesthetic agent concentration by refractometry.

Reference refractivity values have been derived for the anaesthetic agents halothane, isoflurane, enflurane, sevoflurane and desflurane which are traceable to national measurement standards. A simple method and equation have been derived for the application of these data to the measurement of agent concentration by refractometry. The main instrumental sources of uncertainty associated with this...

متن کامل

Improved automatic steam distillation combined with oscillation-type densimetry for determining alcoholic strength in spirits and liqueurs.

The determination of the alcoholic strength in spirits and liqueurs is required to control the labelling of alcoholic beverages. The reference methodology prescribes a distillation step followed by densimetric measurement. The classic distillation using a Vigreux rectifying column and a West condenser is time consuming and error-prone, especially for liqueurs that may have problems with entrain...

متن کامل

Absolute refractometry of dry gas to ±3 parts in 10⁹.

We present a method of measuring the refractive index of dry gases absolutely at 632.8 nm wavelength using a Fabry-Perot cavity with an expanded uncertainty of <3×10⁻⁹ (coverage factor k=2). The main contribution to this uncertainty is how well vacuum-to-atmosphere compression effects (physical length variation) in the cavities can be corrected. This paper describes the technique and reports re...

متن کامل

modeling loss data by phase-type distribution

بیمه گران همیشه بابت خسارات بیمه نامه های تحت پوشش خود نگران بوده و روش هایی را جستجو می کنند که بتوانند داده های خسارات گذشته را با هدف اتخاذ یک تصمیم بهینه مدل بندی نمایند. در این پژوهش توزیع های فیزتایپ در مدل بندی داده های خسارات معرفی شده که شامل استنباط آماری مربوطه و استفاده از الگوریتم em در برآورد پارامترهای توزیع است. در پایان امکان استفاده از این توزیع در مدل بندی داده های گروه بندی ...

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Metrology and Quality Engineering

سال: 2022

ISSN: ['2107-6839', '2107-6847']

DOI: https://doi.org/10.1051/ijmqe/2022007