Absolute frequency referencing for swept dual-comb spectroscopy with midinfrared quantum cascade lasers
نویسندگان
چکیده
A scheme to calibrate a frequency-swept frequency comb against reference laser is developed. Its application dual-comb spectrometer based on midinfrared quantum cascade lasers results in molecular spectra with high-frequency accuracy at fast refresh rates.
منابع مشابه
Frequency comb swept lasers.
We demonstrate a frequency comb (FC) swept laser and a frequency comb Fourier domain mode locked (FC-FDML) laser for applications in optical coherence tomography (OCT). The fiber-based FC swept lasers operate at a sweep rate of 1kHz and 120kHz, respectively over a 135nm tuning range centered at 1310nm with average output powers of 50mW. A 25GHz free spectral range frequency comb filter in the s...
متن کاملAsynchronous midinfrared ultrafast optical parametric oscillator for dual-comb spectroscopy.
Two asynchronous, broadband 3.3 µm pulse trains with a stabilized repetition-rate difference of up to 5 kHz were generated using an ultrafast optical parametric oscillator. The two oscillation channels, each producing ~100 mW average power, ran essentially independently, and weak non-phase-matched sum-frequency mixing between them provided a timing signal that indicated when the asynchronous pu...
متن کاملFrequency Comb Swept Lasers for Optical Coherence Tomography
We demonstrate a frequency comb (FC) swept laser and a frequency comb Fourier domain mode locked (FCFDML) laser for applications in optical coherence tomography (OCT). The fiber-based FC swept lasers operate at a sweep rate of 1kHz and 120kHz, respectively, over a 135nm tuning range centered at 1310nm with average output powers of 50mW. A 25GHz free spectral range frequency comb filter in the c...
متن کاملFrequency modulation spectroscopy by means of quantum-cascade lasers
In this paper we investigate the performance of quantum cascade (QC) lasers for high frequency modulation spectroscopy, particularly using frequency modulation (FM) and two-tone (2T) techniques. The coupling of the rf signal to the QC laser through the cryostat is studied in detail as well as the noise contributions of both the detector and the laser source to the final spectra. The experimenta...
متن کاملDesign Optimization for 4.1-THZ Quantum Cascade Lasers
We present an optimized design for GaAs/AlGaAs quantum cascade lasers operating at 4.1THz. This was based on a three-well active module with diagonal radiative transition. This was performed by modifying the existing model structure, to reduce the parasitic anticrossings (leakage currents) as well as the optical gain linewidth. While the gain FWHM was reduced by more than 50% the gain pea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physical review research
سال: 2023
ISSN: ['2643-1564']
DOI: https://doi.org/10.1103/physrevresearch.5.013047