About power quality monitoring in residential grids

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Change-point detection-based power quality monitoring in smart grids

The enormous economic loss caused by power quality problems (more than $150 billion per year in USA) makes power quality monitoring an important component in power grid.With highly connected fragile digital equipment and appliances, Smart Grid has more stringent timeliness and reliability requirements on power quality monitoring. In this work, we propose a change-point detection theory-based po...

متن کامل

Improvement of Power Quality Index in Distributed Power Grids

This project proposed the new distortion power quality index to replace the previously proposed index. Its computation was carried out based on the load composition rate (LCR) and Euclidean norm of total harmonic distortions (THDs) of the measured voltage and current waveforms at the point of common coupling (PCC). Based on the proposed PQI, the harmonic pollution ranking, which indicates how m...

متن کامل

Power Quality aspects of Smart Grids

This paper gives an overview of the smart grids developments, seen from a power-quality viewpoint; describes the main relations between smart grids and power quality, and goes into some detail for some of the aspects. Different types of real and virtual energy storage are distinguished. Power-quality monitoring in the smart grid is discussed in detail. Further aspects discussed in the paper are...

متن کامل

Improvement power quality in Electrical Distribution Grids with DG by DVR based on ANN Controller

Abstract: Unified Power Flow Controller (UPFC) is one of the FACTS devices which plays a crucial role in simultaneous regulating active and reactive power, improving system load, reducing congestion and cost of production. Therefore, determining the optimum location of such equipment in order to improve the performance of the network is significant. In this paper, WCA algorithm is used to locat...

متن کامل

Power Quality Monitoring using PMU

Voltage sags are the most common power quality disturbance usually associated with power system faults, which can cause huge economic loss, making it the focus of emerging research. The proposed voltage sag detection technique for a single-line-to-ground (SLG) fault is presented using the PMU measurement data for improving the power quality. Various voltage sag detection techniques have been di...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Renewable Energy and Power Quality Journal

سال: 2017

ISSN: 2172-038X,2172-038X

DOI: 10.24084/repqj15.397