BACKGROUND The use of selective internal radiation therapy (SIRT) is rapidly increasing, and the need for quantification and dosimetry is becoming more widespread to facilitate treatment planning and verification. The aim of this project was to develop an anthropomorphic phantom that can be used as a validation tool for post-SIRT imaging and its application to dosimetry. METHOD The phantom de...
متن کاملDevelopment of a physical 3D anthropomorphic breast phantom.
PURPOSE Develop a technique to fabricate a 3D anthropomorphic breast phantom with known ground truth for image quality assessment of 2D and 3D breast x-ray imaging systems. METHODS The phantom design is based on an existing computer model that can generate breast voxel phantoms of varying composition, size, and shape. The physical phantom is produced in two steps. First, the portion of the vo...
متن کاملFeasibility of a 3D-printed anthropomorphic patient-specific head phantom for patient-specific quality assurance of intensity-modulated radiotherapy
This study evaluated the feasibility of utilizing a 3D-printed anthropomorphic patient-specific head phantom for patient-specific quality assurance (QA) in intensity-modulated radiotherapy (IMRT). Contoured left and right head phantoms were converted from DICOM to STL format. Fused deposition modeling (FDM) was used to construct an anthropomorphic patient-specific head phantom with a 3D printer...
متن کاملA proposal for a standard electronic anthropomorphic phantom for radiotherapy.
To create a database of human male and female computed tomography (CT) slices, the National Library of Medicine organized the "Visible Human Project." Since the male and female data sets provided are approximately 269 MB and 915 MB, respectively, both the size and complexity have been reduced. While making the slices accessible to those with limited computing resources, the production of these ...
متن کاملA novel anthropomorphic flow phantom for the quantitative evaluation of prostate DCE-MRI acquisition techniques.
A novel anthropomorphic flow phantom device has been developed, which can be used for quantitatively assessing the ability of magnetic resonance imaging (MRI) scanners to accurately measure signal/concentration time-intensity curves (CTCs) associated with dynamic contrast-enhanced (DCE) MRI. Modelling of the complex pharmacokinetics of contrast agents as they perfuse through the tumour capillar...