A Whole Body Counter Employing Eight Units of Plastic Scintillation Detectors I. γ-Ray Performance of a Plastic Scintillation Detector Unit
نویسندگان
چکیده
منابع مشابه
Investigating the capability of plastic scintillation detectors in design of a muon radiography system by Geant4 code
Imaging and identifying materials with high atomic numbers and densities, especially radioactive materials, is one of the issues that have been especially considered in recent years. Due to some limitations in conventional and old imaging techniques, finding an alternative method is very important. The cosmic muons with an infinite source are one of the sources that have been recently studied f...
متن کاملDosimetric performance and array assessment of plastic scintillation detectors for stereotactic radiosurgery quality assurance.
PURPOSE To compare the performance of plastic scintillation detectors (PSD) for quality assurance (QA) in stereotactic radiosurgery conditions to a microion-chamber (IC), Gafchromic EBT2 films, 60 008 shielded photon diode (SD) and unshielded diodes (UD), and assess a new 2D crosshair array prototype adapted to small field dosimetry. METHODS The PSD consists of a 1 mm diameter by 1 mm long sc...
متن کاملWater-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical consideration.
A minimally perturbing plastic scintillation detector has been developed for the dosimetry of high-energy beams in radiotherapy. The detector system consists of two identical parallel sets of radiation-resistant optical fibre bundles, each connected to independent photomultiplier tubes (PMTs). One fibre bundle is connected to a miniature water equivalent plastic scintillator and so scintillatio...
متن کاملIron absorption. Measurement of ingested iron59 by a human whole-body liquid scintillation counter.
The availability of radioactive isotopes of iron led to the development of reliable methods of studying iron kinetics (1), but the absorption of iron by the gastrointestinal tract was still determined indirectly by the amount of unabsorbed iron excreted in the stools or by quantification of isotopic iron incorporated into hemoglobin (2-7). The availability of a whole-body counter in a clinical ...
متن کاملWater-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements.
The properties of a new scintillation detector system for use in dosimetry of high-energy beams in radiotherapy have been measured. The most important properties of these detectors are their hgh spatial resolution and their nearly water-equivalence. Measurements have shown that they have excellent reproducibility and stability, and a linear response versus dose-rate. It is also shown that they ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: RADIOISOTOPES
سال: 1965
ISSN: 1884-4111,0033-8303
DOI: 10.3769/radioisotopes.14.1