منابع مشابه

Performance Evaluation for a 100 W Stirling Engine

A small 100 W displacer-type Stirling engine, Ecoboy-SCM81 has being developed by a committee of the Japan Society of Mechanical Engineers. The engine contains unique features, including an expansion cylinder which is heated by either combustion gas or direct solar energy. Also, a simple cooling system rejects heat from the working gas. A displacer piston has both heating and cooling inner tube...

متن کامل

Low-power cryocooler survey

A cryocooler survey has been performed on data of 235 cryocoolers, with cooling powers below some tens of watts and operating between 4 and 120 K. The state-of-the-art is discussed and trends are investigated on cooling performance, mass and size, cost, lifetime and reliability. The data were compared with earlier surveys to explore historical trends. Improvements in cooling performance were ma...

متن کامل

Crystal Structure of Nonaaquayttrium(III) Bromate at 100 K

The structure of the nonaaquayttrium (III) bromate, [Y(H2O)9](BrO3)3, at low temperature (100 K) has been studied by means of single-crystal X-ray diffraction. Crystallography shows a hexagonal unit cell, space group P63/mmc (No. 194) with Z = 2, a = b = 11.7104(11) Å, c = 6.6259(5) Å and V = 786.90(12) Å3 at 100 K. The hydra...

متن کامل

Cryogenic cooling with cryocooler on a rotating system.

We developed a system that continuously maintains a cryocooler for long periods on a rotating table. A cryostat that holds the cryocooler is set on the table. A compressor is located on the ground and supplies high-purity (>99.999%) and high-pressure (1.7 MPa) helium gas and electricity to the cryocooler. The operation of the cryocooler and other instruments requires the development of interfac...

متن کامل

Closed - cycle gas flow system for cooling of high T , d . c . SQUID magnetometers

A high T, d.c. SQUID based magnetometer for magnetocardiography is currently under development at the University of Twente. Since such a magnetometer should be simple to use, the cooling of the system can be realized most practically by means of a cryocooler. A closed-cycle gas flow cooling system incorporating such a cooler has been designed, constructed and tested. The aimed resolution of the...

متن کامل