A two-lens collimating system with one aspherical surface
نویسندگان
چکیده
The article describes the method of calculating optical parameters second, aspherical lens based on known first spherical in a two-lens collimating system. allows to write parametric equation aspheric profile an explicit form.
منابع مشابه
Aspherical lens design.
Given a three-dimensional surface G, not necessarily rotationally symmetric, and away from a point source, we design a surface F such that the lens sandwiched between the two surfaces refracts radiation into a given direction or into a given point. The surface F satisfies a system of first-order partial differential equations that can be solved in terms of G and the refractive indices of the me...
متن کاملAspherical Lens Design and Imaging
We design freeform lenses refracting an arbitrarily given incident field into a given fixed direction. In the near field case, we study the existence of lenses refracting a given bright object into a predefined image. We also analyze the existence of systems of mirrors that solve the near field and the far field problems for reflection.
متن کاملQueueing Inventory System in a Two-level Supply Chain with One-for-One Ordering Policy
Consider a two-level inventory system consisting of one supplier and one retailer. The retailer faces a Poisson demand with a known rate and applies base stock (one-for-one ordering) policy. That is, his inventory position is set to a pre-determined level, so the demand pattern is transferred exactly to the supplier. The supplier has an inventory system and a service unit with exponentially dis...
متن کاملFreeform lens design for LED collimating illumination.
We present a simple freeform lens design method for an application to LED collimating illumination. The method is derived from a basic geometric-optics analysis and construction approach. By using this method, a highly collimating lens with LED chip size of 1.0 mm × 1.0 mm and optical simulation efficiency of 86.5% under a view angle of ± 5 deg is constructed. To verify the practical performanc...
متن کاملImproved illumination system of laparoscopes using an aspherical lens array.
The current fiber-based illumination systems of laparoscopes are unable to uniformly illuminate a large enough area in abdomen due to the limited numerical aperture (NA) of the fiber bundle. Most energy is concentrated in a small region at the center of the illumination area. This limitation becomes problematic in laparoscopes which require capturing a wide field of view. In this paper, we prop...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: GEORGIAN SCIENTISTS
سال: 2022
ISSN: ['2667-9760']
DOI: https://doi.org/10.52340/gs.2022.04.05.29