منابع مشابه
The Channel Multiplier Cathode-ray Tube
This paper describes a new approach to cathode-ray tube design aimed at achieving a significant depth reduction. The addressing function of the electron beam has been separated from the light generation process by a channel electron multiplier array, allowing the use of a novel deflection system based on a low-power scanning beam. Monochrome versions of the thin tube have been made with a 12" (...
متن کاملLuminance artifacts of cathode-ray tube displays for vision research.
Phosphor persistence, video bandwidth, DC restoration and high-voltage regulation affect the appearance of images presented on cathode-ray tubes (CRTs), potentially resulting in differences between nominal and actual stimuli. We illustrate these effects by measuring physical parameters of horizontal and vertical static and counter-phase flickering gratings, and we illustrate problems for vision...
متن کاملCathode Ray Tube (crt) Lead Glass: Lead Leaching Study after a Chelating Agent Treatment
This study is focused on the removal of leachable lead present in CRT (cathode ray tube) glass employing different chelating agents, NTA (nitrilotriacetic acid) and ATMP (amino trimetilen phosphonic acid), and then on the evaluation of their extractive capability. The operating conditions are the following: T=80°C, t=1h, pH=10, solid/liquid weight ratio=1/10, reagent concentration= 0.1 M. After...
متن کاملEvaluating the economic viability of a material recovery system: the case of cathode ray tube glass.
This paper presents an analysis of the material recovery system for leaded glass from cathode ray tubes (CRTs) using a dynamic material flow analysis. In particular, the global mass flow of primary and secondary CRT glass and the theoretical capacities for using secondary CRT glass to make new CRT glass are analyzed. The global mass flow analysis indicates that the amount of new glass required ...
متن کاملAn intelligent system for tuning magnetic field of a cathode ray tube deflection yoke
This short communication concerns identification of the number of magnetic correction shunts and their positions for deflection yoke tuning to correct the misconvergence of colours of a cathode ray tube. The misconvergence of colours is characterised by the distances measured between the traces of red and blue beams. The method proposed consists of two phases, namely, learning and optimisation....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Journal of the Institute of Television Engineers of Japan
سال: 1969
ISSN: 1884-9644
DOI: 10.3169/itej1954.23.186