A Technique to Stabilise the Herbert–Huene Jig During Scaphoid Fracture Fixation

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Scaphoid Fracture Fixation with an Acutrak® Screw

We report a case of fixation of a scaphoid fracture using an Acutrak(®) screw. This screw is cannulated and headless, which allows it to be implanted below the surface of the bone. It uses the same concept of variable thread pitch as the Herbert screw, but unlike the Herbert screw, is fully threaded, with continuously varying pitch along its length. This variable pitch creates constant compress...

متن کامل

The Importance of Screw Design in Scaphoid Fracture Fixation

The purpose of this study was to determine the influence of gender, screw design, and the approach on maximal screw length in scaphoid fracture fixation. Measurements were performed on 3D reconstructions of 20 CT scans of normal scaphoids. A comparison was made between 15 different available screw designs and between volar and dorsal screw placement. The length of the scaphoid along its central...

متن کامل

Scaphoid fracture: functional outcome following fixation with Herbert Screw.

BACKGROUND Most scaphoid fractures though heal uneventfully with cast treatment, immobilization with cast is associated with complication like wrist stiffness. Open reduction and fixation with Herbert Screw though technically demanding procedure can yield excellent results and prevents complication like nonunions and loss of wrist function. OBJECTIVES To assess clinical outcome and radiologic...

متن کامل

Trans-scaphoid perilunate fracture dislocation: 'notjust a scaphoid fracture'.

Rowan CH, Downing ND. BMJ Case Rep 2017. doi:10.1136/bcr-2017-221041 Description Perilunate dislocations are uncommon high-energy injuries which are missed in approximately 25% of cases on initial presentation. We present the X-rays of a 25-year-old man who fell from a height of approximately 2 metres onto an extended wrist. Plain radiographs (figure 1) show classical signs of a trans-scaphoid ...

متن کامل

Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture

Breakage of DHS guide wire during surgery and its migration into the pelvis through the hip joint is a rare complication and its removal can be very challenging for the surgeon. We share our experience of a similar case wherein we used an ‘iliofemoral’ approach to successfully remove the broken transfixing guidewire from the hip joint. Although iliofemoral approach is similar to the lateral win...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Annals of The Royal College of Surgeons of England

سال: 2009

ISSN: 0035-8843,1478-7083

DOI: 10.1308/rcsann.2009.91.7.617