A Study on the Thermal Characteristics of Horizontal Ground Heat Exchanger using Thermal Response Test

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect Of Seasonal Variation On Thermal Performance Of Horizontal Slinky-Loop Ground Heat Exchanger

For ground-source heat pump (GSHP) installations, it is important to predict the thermal performance and economic feasibility prior to the introduction of the system. Numerical modelling can be used as an analytical method to accurately predict the thermal performance of such system. It is desirable that the modelling to incorporate seasonal variation during long period of operation, which woul...

متن کامل

Intermediate Heat Exchanger Dynamic Thermal Response

This report presents UCB progress in developing a comprehensive thermal and fluid dynamics model for the NGNP intermediate heat exchanger (IHX) and other compact heat exchangers. For nuclear hydrogen applications, an IHX is required to transfer heat from high temperature and high-pressure primary helium coolant to a hydrogen production process. An intermediate heat transfer loop is used for the...

متن کامل

Transient thermal study of recuperative tube in tube heat exchanger operating in refrigeration system using experimental test and mathematical simulation

Joule-Thomson cooling systems are used in refrigeration and liquefaction processes. There are extensive studies on Joule-Thomson cryogenic systems, but most of them coverage steady state conditions or lack from experimental data. In the present work, transient thermal behavior of Joule-Thomson cooling system including counter current helically coiled tube in tube heat exchanger, expansion valve...

متن کامل

Distributed Thermal Response Test on a U-pipe Borehole Heat Exchanger

In a Distributed Thermal Response Test (DTRT) the ground thermal conductivity and borehole thermal resistance are determined at many instances along the borehole. Here, such a test is carried out at a 260 m deep water filled energy well, equipped with a U-pipe borehole heat exchanger, containing an aqueous solution of ethanol as working fluid. Distributed temperature measurements are carried ou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the Korea Academia-Industrial cooperation Society

سال: 2016

ISSN: 1975-4701

DOI: 10.5762/kais.2016.17.3.24