A Study on Control Method of Thermal Storage Tank for Varying Thermal Load in Heat Pump Water Heater

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical study of fluid flow and heat transfer in a gas-tank water heater

Influence of a vent hood at the exit of exhaust flue gas and flue baffles in the firetube on the temperature and flow fields of a gas tank water heater, as well as thestructure and amount of heat transferred to the water tank has been studiednumerically using two-dimensional steady state finite element simulation.Observations show that without a vent hood, there is a downward gas flow in theflu...

متن کامل

Study on the Performance of a Ground Source Heat Pump System Assisted by Solar Thermal Storage

A ground source heat pump system (GSHPS) utilizes a relatively stable underground temperature to achieve energy-saving for heating and cooling in buildings. However, continuous long-term operation will reduce the soil temperature in winter, resulting in a decline in system performance. In this research, in order to improve the system performance of a GSHPS, a ground heat pump system integrated ...

متن کامل

On the Behavior of Different PCMs in a Hot Water Storage Tank against Thermal Demands

Advantages, such as thermal storage improvement, are found when using PCMs (Phase Change Materials) in storage tanks. The inclusion of three different types of materials in a 60 l test tank is studied. Two test methodologies were developed, and four tests were performed following each methodology. A thermal analysis is performed to check the thermal properties of each PCM. The distributions of ...

متن کامل

Experimental Study on the Performance of Water Source Trans-Critical CO2 Heat Pump Water Heater

The effect of the discharge pressure on the performance of the trans-critical CO2 heat pump with a low gas-cooler outlet temperature is experimentally investigated on a test rig of water source heat-pump water heater. The optimal discharge pressure of the trans-critical CO2 heat pump is investigated under different external operation conditions. When the tap-water temperature is low, the charac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Korean Journal of Air-Conditioning and Refrigeration Engineering

سال: 2012

ISSN: 1229-6422

DOI: 10.6110/kjacr.2012.24.4.330