A study of the beam-specific interplay effect in proton pencil beam scanning delivery in lung cancer
نویسندگان
چکیده
منابع مشابه
Golden beam data for proton pencil-beam scanning.
Proton, as well as other ion, beams applied by electro-magnetic deflection in pencil-beam scanning (PBS) are minimally perturbed and thus can be quantified a priori by their fundamental interactions in a medium. This a priori quantification permits an optimal reduction of characterizing measurements on a particular PBS delivery system. The combination of a priori quantification and measurements...
متن کاملDynamic Delivery Planning in Iba Proton Pencil Beam
Pencil Beam Scanning is a dynamic beam delivery system developed for proton therapy. The radiation field necessary to reach in a fast and robust way a prescribed 3D dose distribution is obtained by accurately controlling both the extraction of the beam from a 235 MeV accelerator and the motion of the beam spot thanks to scanning magnets. This paper focuses on the trajectory planning aspect of t...
متن کاملComparison of multi‐institutional Varian ProBeam pencil beam scanning proton beam commissioning data
PURPOSE Commissioning beam data for proton spot scanning beams are compared for the first two Varian ProBeam sites in the United States, at the Maryland Proton Treatment Center (MPTC) and Scripps Proton Therapy Center (SPTC). In addition, the extent to which beams can be matched between gantry rooms at MPTC is investigated. METHOD Beam data for the two sites were acquired with independent dos...
متن کاملBeam‐specific planning target volumes incorporating 4D CT for pencil beam scanning proton therapy of thoracic tumors
The purpose of this study is to determine whether organ sparing and target coverage can be simultaneously maintained for pencil beam scanning (PBS) proton therapy treatment of thoracic tumors in the presence of motion, stopping power uncertainties, and patient setup variations. Ten consecutive patients that were previously treated with proton therapy to 66.6/1.8 Gy (RBE) using double scattering...
متن کاملDevelopment of Optical Fiber Based Measurement System for the Verification of Entrance Dose Map in Pencil Beam Scanning Proton Beam
This study describes the development of a beam monitoring system for the verification of entrance dose map in pencil beam scanning (PBS) proton therapy based on fiber optic radiation sensors (FORS) and the validation of this system through a feasibility study. The beam monitoring system consisted of 128 optical fibers optically coupled to photo-multiplier tubes. The performance of the beam moni...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Oncologica
سال: 2017
ISSN: 0284-186X,1651-226X
DOI: 10.1080/0284186x.2017.1293287