A study of diffraction-based chitosan leaky waveguide (LW) biosensors

نویسندگان

چکیده

Chitosan diffraction-based leaky waveguides were shown to have good reproducibility and be suitable for monitoring the binding of anti-biotin antibody biotin in presence physiological levels serum albumin.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical leaky waveguide biosensors for the detection of organophosphorus pesticides.

Organophosphorus (OP) pesticides can be rapidly detected by integrating organophosphorus hydrolase with an optical leaky waveguide biosensor. This enzyme catalyses the hydrolysis of a wide range of organophosphorus compounds causing an increase in the pH. Thus, the direct detection of OP is possible by monitoring of the pH changes associated with the enzyme's activity. This article describes th...

متن کامل

construction and validation of a computerized adaptive translation test (a receptive based study)

آزمون انطباقی رایانه ای (cat) روشی نوین برای سنجش سطح علمی دانش آموزان می باشد. در حقیقت آزمون های رایانه ای با سرعت بالایی به سمت و سوی جایگزین عملی برای آزمون های کاغذی می روند (کینگزبری، هاوسر، 1993). مقاله حاضر به دنبال آزمون انطباقی رایانه ای برای ترجمه می باشد. بدین منظور دو پرسشنامه مشتمل بر 55 تست ترجمه میان 102 آزمودنی و 10 مدرس زبان انگلیسی پخش گردید. پرسشنامه اول میان 102 دانشجوی س...

Waveguide-Based Biosensors for Pathogen Detection

Optical phenomena such as fluorescence, phosphorescence, polarization, interference and non-linearity have been extensively used for biosensing applications. Optical waveguides (both planar and fiber-optic) are comprised of a material with high permittivity/high refractive index surrounded on all sides by materials with lower refractive indices, such as a substrate and the media to be sensed. T...

متن کامل

Reducing the temperature sensitivity of SOI waveguide-based biosensors

Label-free photonic biosensors fabricated on silicon-on-insulator (SOI) can provide compact size, high evanescent field strength at the silicon waveguide surface, and volume fabrication potential. However, due to the large thermo optic coefficient of water-based biosamples, the sensors are temperature-sensitive. Consequently, active temperature control is usually used. However, for low cost app...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Analyst

سال: 2021

ISSN: ['1364-5528', '0003-2654']

DOI: https://doi.org/10.1039/d1an00940k