A Study for Narrow Beam Dosimetry Using a Radiophotoluminescent Glass Rod Dosimeter
نویسندگان
چکیده
منابع مشابه
gamma dosimetry with glass dosimeter
the radiophotoluminescence property of some materials makes it possible to use them for dosimetry purposes. the silver activated metaphoshate glass 1 as an rpl dosimeter when exposed to x. or y radiations , forms fluorescent centers with long lived states ( metastate ). the silver ions (ag+) in unirradiated state produces vacancies when energy is supplied by irradiation the release of electrons...
متن کاملEstimating intraocular pressure using a glass rod.
Four masked examiners studied the usefulness of the glass-rod for estimating intraocular pressure (IOP) in a living, anesthetized rabbit eye manometrically set to 135 different random values. With training, the average error in IOP estimation improved from 7.42 +/- 5.56 mmHg to 5.13 +/- 4.48 mmHg. Gentle palpation of the corneal apex with a glass-rod provides tactile and visual clues that may a...
متن کاملFeasibility Study on Applying Radiophotoluminescent Glass Dosimeters for CyberKnife SRS Dose Verification
CyberKnife is one of multiple modalities for stereotactic radiosurgery (SRS). Due to the nature of CyberKnife and the characteristics of SRS, dose evaluation of the CyberKnife procedure is critical. A radiophotoluminescent glass dosimeter was used to verify the dose accuracy for the CyberKnife procedure and validate a viable dose verification system for CyberKnife treatment. A radiophotolumines...
متن کاملElectron Beam Dosimetry in Heterogeneous Phantoms Using a MAGIC Normoxic Polymer Gel
Introduction: Nowadays radiosensitive polymer gels are used as a reliable dosimetry tool for verification of 3D dose distributions. Special characteristics of these dosimeters have made them useful for verification of complex dose distributions in clinical situations. The aim of this work was to evaluate the capability of a normoxic polymer gel to determine electron dose distributions in differ...
متن کاملDosimetry intercomparison using a 35-keV X-ray synchrotron beam.
The purpose of this study was to compare dose measurements using ion chamber and radiochromic film dosimetry for a 35-keV synchrotron beam useful for Auger electron therapy. A 1.3-GeV electron beam, transported through a 3-pole superconducting wiggler magnet, produced a polychromatic photon beam from which a 35-keV beam (3.3 mm Al HVL) was selected using a monochromator. A 2.8 cm x 2.5 cm field...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Japanese Journal of Radiological Technology
سال: 2004
ISSN: 0369-4305,1881-4883
DOI: 10.6009/jjrt.kj00000922528