A Stand-Alone Smart Camera System for Online Post-Earthquake Building Safety Assessment
نویسندگان
چکیده
منابع مشابه
Operation of Stand Alone PV Generating System for Supplying Unbalanced AC Loads
This paper describes a DC isolated network which is fed with Distributed Generation (DG) from photovoltaic (PV) renewable sources for supplying unbalanced AC loads. The battery energy storage bank has been connected to the DC network via DC/DC converter to control the voltage of the network and optimize the operation of the PV generation units. The PV arrays are connected to the DC network ...
متن کاملAutomatic generation of smart earthquake-resistant building system: Hybrid system of base-isolation and building-connection
A base-isolated building may sometimes exhibit an undesirable large response to a long-duration, long-period earthquake ground motion and a connected building system without base-isolation may show a large response to a near-fault (rather high-frequency) earthquake ground motion. To overcome both deficiencies, a new hybrid control system of base-isolation and building-connection is proposed and...
متن کاملNonlinear Control for Positive Output Super Lift Luo Converter in Stand Alone Photovoltaic System
This paper proposes a stand-alone photovoltaic (PV) system based on a DC-DC positive output super lift Luo (POSLL) converter. A conventional sliding mode control, a sliding mode controller using a simple sign function and a linear controller using proportional integrator (PI) are used for the control of the PV panel voltage and POSLL converter inductor current and these methods are compared tog...
متن کاملEnergy Storage for a Stand-alone Wind Energy Conversion System
This paper deals with a wind-based stand-alone generating unit with Permanent Magnet Synchronous Generator (PMSG) and a Lead Acid Battery (LAB) for energy storage, during wind speed variation as well as transient performance under variable load. The main purpose is to supply 230 V/50 Hz domestic appliances through a single-phase inverter. Simulations and experimental results validate the stabil...
متن کاملBuilding Damage Detection from Post-earthquake
The collapsed buildings due to earthquake were detected from post-event aerial images using watershed segmentation algorithm. The objective was to detect the collapsed buildings based on the analysis of the cast shadows. The building boundaries were available and stored in a GIS as vector polygons. The building polygons were utilized to perform assessments in a building specific manner. The app...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sensors
سال: 2020
ISSN: 1424-8220
DOI: 10.3390/s20123374