A Stable Solid-Reference Electrode of BiCuVOx/Perovskite-Oxide for Potentiometric Solid Electrolyte CO2 Sensor
نویسندگان
چکیده
منابع مشابه
A GdAlO3 Perovskite Oxide Electrolyte-Based NOx Solid-State Sensor
NOx is a notorious emission from motor vehicles and chemical factories as the precursor of acid rain and photochemical smog. Although zirconia-based NOx sensors have been developed and showed high sensitivity and selectivity at a high temperature of above 800 °C, they fail to show good performance, and even don't work at the typical work temperature window of the automotive engine (<500 °C). It...
متن کاملA planar solid-state potentiometric CO2 sensor in thick-film technology for breath analysis
In this work, a planar solid-state potentiometric CO2 sensor for medical applications of the type CO2, O2, Au, Li2CO3-BaCO3 | Nasicon | Na2Ti6O13-TiO2, Au, O2, CO2 was developed in thick-film technology. Due to an integrated screen-printed platinum heater on the rear side, the sensor can be applied without changing its working temperature of 525°C in the main flow of the respiratory air of an i...
متن کاملOperando X-ray Investigation of Electrode/Electrolyte Interfaces in Model Solid Oxide Fuel Cells
We employed operando anomalous surface X-ray diffraction to investigate the buried interface between the cathode and the electrolyte of a model solid oxide fuel cell with atomic resolution. The cell was studied under different oxygen pressures at elevated temperatures and polarizations by external potential control. Making use of anomalous X-ray diffraction effects at the Y and Zr K-edges allow...
متن کاملA Solid-State Thin-Film Ag/AgCl Reference Electrode Coated with Graphene Oxide and Its Use in a pH Sensor
In this study, we describe a novel solid-state thin-film Ag/AgCl reference electrode (SSRE) that was coated with a protective layer of graphene oxide (GO). This layer was prepared by drop casting a solution of GO on the Ag/AgCl thin film. The potential differences exhibited by the SSRE were less than 2 mV for 26 days. The cyclic voltammograms of the SSRE were almost similar to those of a commer...
متن کاملCOBALT PHTHALOCYANINE MODIFIED CARBON PASTE ELECTRODE AS A POTENTIOMETRIC SENSOR FOR DETERMINATION OF ASCORBIC ACID
A carbon Paste electrode modified with cobalt (II) phthalocyanine (CoPC) was used as a sensitive potentiometric sensor for determination of ascorbic acid in aqueous solutions. The potential response of the electrode is a linear function of ascorbic acid concentration over the range 5 10 to 10 M (?1- 1800 µg ML ) with a Nernstian slope of 56 mV at pH 7. The limit of detection was 0.2 µg ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Ceramic Society of Japan
سال: 2007
ISSN: 1882-0743,1348-6535
DOI: 10.2109/jcersj2.115.706