A skew-slit collimator for small-animal SPECT.

UNLABELLED The main objective of this work was the development of a skew-slit collimator for small-animal SPECT to replace the state-of-the-art multipinhole collimator. METHODS A pinhole forms a cone-beam imaging geometry. If the collimator rotates around the object in a circular orbit, the projection measurements acquired by the cone-beam imaging geometry are incomplete and not enough for ar...

متن کامل

Evaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study

Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...

متن کامل

CdZnTe strip detector SPECT imaging with a slit collimator.

In this paper, we propose a CdZnTe rotating and spinning gamma camera attached with a slit collimator. This imaging system acquires convergent planar integrals of a radioactive distribution. Two analytical image reconstruction algorithms are proposed. Preliminary phantom studies show that our small CdZnTe camera with a slit collimator outperforms a larger NaI(Tl) camera with a pinhole collimato...

متن کامل

evaluation of the performance of parallel-hole collimator for high resolution small animal spect: a monte carlo study

introduction: image quality and accuracy of in vivo activity quantification in spect are affected by collimator penetration and scatter components, especially in high energy imaging. these phenomena highly depend on the collimator characteristic and photon energy. the presence of penetrated and scattered photons from collimator in spect images degrades spatial resolution, contrast and image qua...

متن کامل

An analytical algorithm for skew-slit imaging geometry with nonuniform attenuation correction.

The pinhole collimator is currently the collimator of choice in small animal single photon emission computed tomography (SPECT) imaging because it can provide high spatial resolution and reasonable sensitivity when the animal is placed very close to the pinhole. It is well known that if the collimator rotates around the object (e.g., a small animal) in a circular orbit to form a cone-beam imagi...