A simplified methodology: pH sensing using an in situ fabricated Ir electrode under neutral conditions

نویسندگان

چکیده

Abstract Herein, a simplified fabrication method for the producing of pH-sensitive iridium electrode is developed. The in situ electrochemical an oxide film optimized and shown to be achievable under neutral conditions rather than acidic hitherto employed. formation pH sensitive Ir(III/IV) hydrous confirmed via XPS. amperometric pH-sensing properties this electrochemically generated material were investigated using square wave voltammetry. In range 2–13, redox signal has dependency 86.1 ± 1.1 mV per unit midpoint potentials with uncertainties being 0.01–0.05 pH. Finally, newly developed sensor was used measure natural water sample excellent results as compared conventional glass probe.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

pH electrode performance under automated management conditions

pH is frequently measured in laboratories, but to have confidence in the results it is necessary to know that it was measured properly. For an electrode to give accurate results it must be treated well and calibrated correctly. In this paper, an automated system for pH measurement is described; the system uses the operational pH scale and calibrates using two or three buffer solutions, taking p...

متن کامل

Pyrite oxidation under initially neutral pH conditions

Introduction Conclusions References Tables Figures Back Close Full Screen / Esc Biogeosciences Discussions This discussion paper is/has been under review for the journal Biogeosciences (BG). Please refer to the corresponding final paper in BG if available. Abstract Introduction Conclusions References Tables Figures Back Close Full Screen / Esc Abstract Hydrogen peroxide (H 2 O 2) at a micromola...

متن کامل

In-situ preconcentration, and electrochemical sensing of zinc(II) and copper(II) based on ionic liquid mediated hollow fiber-modified pencil graphite electrode using response surface methodology

A single-use electrochemical sensor using ionic liquid mediated hollow fiber-graphite working electrode was fabricated for the first time. The screening tool was developed by coupling this electrode with differential pulse voltammetry (DPV) for in-situ pre-concentration and determination of Zn(II) and Cu(II). In our plot, porous polypropylene hollow fiber membrane was divided into pieces of 2 c...

متن کامل

An in situ ATR-IR spectroscopy study of aluminas under aqueous phase reforming conditions.

High temperature/pressure in situ Attenuated Total Reflection Infrared (ATR-IR) spectroscopy was used to investigate the phase transformation of support γ-Al2O3 into boehmite (AlO(OH)) under the hydrothermal conditions of aqueous phase reforming (APR). Activation energy barriers of boehmite formation in hot compressed water at temperatures between 150 and 180 °C were calculated to be 15.9 ± 4.8...

متن کامل

In-situ preconcentration, and electrochemical sensing of Zinc(II) and Copper(II) based on ionic liquid mediated hollow fiber-modified pencil graphite electrode using response surface methodology

A single-use electrochemical sensor using ionic liquid mediated hollow fiber-graphite working electrode was fabricated for the first time. The screening tool was developed by coupling this electrode with differential pulse voltammetry (DPV) for in-situ pre-concentration and determination of Zn(II) and Cu(II). In our plot, porous polypropylene hollow fiber membrane divided into pieces of 2 cm, t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Solid State Electrochemistry

سال: 2021

ISSN: ['1433-0768', '1432-8488']