A SIMPLE REFLECTION GONIOMETER
نویسندگان
چکیده
منابع مشابه
Diffuse reflection diameter in simple polygons
We prove a conjecture of Aanjaneya, Bishnu, and Pal that the maximum number of diffuse reflections needed for a point light source to illuminate the interior of a simple polygon with n walls is bn/2c − 1. Light reflecting diffusely leaves a surface in all directions, rather than at an identical angle as with specular reflections.
متن کاملA simple demonstration of frustrated total internal reflection
We describe a quantitative and inexpensive method of demonstrating frustrated total internal reflection based on the attenuation of a laser beam through a wedge-shaped air gap between two glass prisms. An advantage of this method is that the thickness of the air gap can be determined by observing interference effects with only a slight modification of the setup. The experiment avoids the need t...
متن کاملThe reliability of a smartphone goniometer application compared with a traditional goniometer for measuring first metatarsophalangeal joint dorsiflexion
BACKGROUND Adequate sagittal plane motion of the first metatarsalphalangeal joint (1st MTPJ) is important during normal gait and goniometric measurement is commonly used as a diagnostic and outcome assessment tool. We aimed to determine the intra and inter-rater reliability together with the concurrent validity of a universal plastic goniometer (UG) and a smartphone applicationlication (Dr G) f...
متن کامل[Development of posture measuring apparatus using goniometer and inclinometer. 2. Fixation, precision and calibration of goniometer].
A new posture measuring apparatus was developed for time and motion study in the field of industrial health. This apparatus records working postures by measuring angles of joints and trunk inclination. The angles of joints were measured by the newly developed goniometers which use the bending loss of rubber optical fibers. This paper presents results of studies made on the fixation, precision a...
متن کاملGoniometer Crosstalk Compensation for Knee Joint Applications
Electrogoniometers are prone to crosstalk errors related to endblocks rotation (general crosstalk) and to the characteristics of each sensor (individual crosstalk). The aim of this study was to assess the crosstalk errors due to endblock misalignments and to propose a procedure to compensate for these errors in knee applications. A precision jig was used to simulate pure ± 100° flexion/extensio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Science
سال: 1908
ISSN: 0036-8075,1095-9203
DOI: 10.1126/science.27.702.929-a