A Sensitive Chemiluminescence Method for Determination of Hydroquinone and Catechol
نویسندگان
چکیده
منابع مشابه
A Sensitive Chemiluminescence Method for Determination of Hydroquinone and Catechol
A novel flow-injection chemiluminescence(CL)method has been developed for the determination of hydroquinone (HQ) and catechol (CT), based on their inhibition of the chemiluminescence reaction of luminol–KMnO4–β-cyclodextrin (β-CD). It was found that β-cyclodextrin could effectively enhance the chemiluminescence produced from the reaction of luminol with KMnO4 in basic media. The proposed method...
متن کاملThe determination of catechol, phenol, and hydroquinone in urine.
There have been many methods devised for the determination of urinary phenols based on calorimetric, gravimetric, and titrimetric procedures, but few of them include quantitative determinations of hydroquinone and catechol. These two phenols are produced in considerable amounts in animals exposed to benzene (1) and since we wished to study this problem further a convenient method of analysis ha...
متن کاملthe innovation of a statistical model to estimate dependable rainfall (dr) and develop it for determination and classification of drought and wet years of iran
آب حاصل از بارش منبع تأمین نیازهای بی شمار جانداران به ویژه انسان است و هرگونه کاهش در کم و کیف آن مستقیماً حیات موجودات زنده را تحت تأثیر منفی قرار می دهد. نوسان سال به سال بارش از ویژگی های اساسی و بسیار مهم بارش های سالانه ایران محسوب می شود که آثار زیان بار آن در تمام عرصه های اقتصادی، اجتماعی و حتی سیاسی- امنیتی به نحوی منعکس می شود. چون میزان آب ناشی از بارش یکی از مولفه های اصلی برنامه ...
15 صفحه اولA cost effective and sensitive method for the determination of ammonia concentration in nanocrystal mordenite
The reduction capacity of ammonia while present even at ppm level can be demonstrated by the increased encounter probability between ammonia and methylene blue dye (MB+) incorporated in nanomordenite and Na-MOR zeolites. The rate of reduction methylene blue dye by ammonia on the surface nanomordenite zeolite is faster than Na-mordenite (Na-MOR) zeolite.Because nanomordenite zeolite with high si...
متن کاملA cost effective and sensitive method for the determination of ammonia concentration in nanocrystal mordenite
The reduction capacity of ammonia while present even at ppm level can be demonstrated by the increased encounter probability between ammonia and methylene blue dye (MB+) incorporated in nanomordenite and Na-MOR zeolites. The rate of reduction methylene blue dye by ammonia on the surface nanomordenite zeolite is faster than Na-mordenite (Na-MOR) zeolite.Because nanomordenite zeolite with high si...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sensors
سال: 2007
ISSN: 1424-8220
DOI: 10.3390/s7040578