A Sealed Metal Argon Ionization Chamber (Argonion)
نویسندگان
چکیده
منابع مشابه
Study of Neutron-Induced Ionization in Helium and Argon Chamber Gases
We present studies of Heliumand Argon-filled ionization chambers exposed to intense neutron fluxes from PuBe neutron sources (En = 1− 10 MeV). The sources emit about 10 neutrons per second. The number of ion pairs in the chamber gas volume per incident neutron is derived. While limited in precision because of a large gamma ray background from the PuBe sources, our results are consistent with th...
متن کاملIonization of liquid argon by a particles
From an analysis of electron pulses in liquid argon produced by a particles the average energy required to form an ion pair is evaluated, assurmng JaEk’s theory of columnar recombination is valid. The mean value of 26.0 ev found in this way agrees well with the corresponding value of 26.4 ev for a particles m argon gas. Application of Jaffk’s theory to the liquid state is discussed, and from th...
متن کاملEvaluation of dosimetry a performance parameter for a homemade farmer-type ionization chamber according to IEC60731
Introduction: Due to its simplicity, fast response and high reliability, ion chamber detectors are one of the most suitable dosimetry instruments for X and gamma rays. The dosimeter of photon beams, which used in radiotherapy centers, requires high accuracy and should pass requirements of IEC 60731 standards. About 80 percent of the IEC 60731 standard tests such as stabil...
متن کاملThe Ionization of Argon and Neon by Neutral Argon Beams.
As a result of the discovery of Kallmann and Rosent"2 that the probability of charge transfer is very great for gas ions moving in a gas of their own molecular or atomic species, the possibility of obtaining an atomic beam of high intensity is at once indicated. Since the charge transfer itself takes place without altering the translatory energy of the moving ion, the translatory energy of the ...
متن کاملNIST Ionization Chamber “A” Sample-Height Corrections
For over 30 years scientists in the NIST radioactivity group have been using their pressurized ionization chamber "A" (PIC "A") to make measurements of radioactivity and radioactive half-lives. We now have evidence that some of those reported measurements were incorrect due to slippage of the source positioning ring over time. The temporal change in the holder caused an error in the source-heig...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Nuclear Science
سال: 1981
ISSN: 0018-9499,1558-1578
DOI: 10.1109/tns.1981.4331650