منابع مشابه
A Scleral Buckling Procedure.
THE past few years have seen the rapid development of scleral buckling procedures for the treatment of retinal separation (Cavka, 1959; Schepens, Okamura, and Brockhurst, 1957; Schepens, Okamura, Brockhurst, and Regan, 1960; Fison, McAuley, Meyer-Schwickerath, and Trevor-Roper, 1960). About 6 years ago I first used the lamellar scleral flap to cover the area of resection. The flap covered the k...
متن کاملPreserved scleral patch graft for unexpected extreme scleral thinning found at the scleral buckling procedure: A case report
Pre-existing scleral pathology is an important risk factor for globe rupture during scleral buckling procedures. We report here, the surgical management of an unexpected scleral pathology found at the scleral buckling procedure in a retinal detachment patient. A 77-year-old white female with retinal detachment underwent a scleral buckling procedure. The surgery was converted into a scleral graf...
متن کاملScleral Buckling with Chandelier Illumination
Scleral buckling is a highly successful technique for the repair of rhegmatogenous retinal detachment that requires intra-operative examination of the retina and treatment of retinal breaks via indirect ophthalmoscopy. Data suggest that scleral buckling likely results in improved outcomes for many patients but is declining in popularity, perhaps because of significant advances in vitrectomy ins...
متن کاملOne "8"-shaped scleral suture to treat rhegmatogenous retinal detachment: a refined procedure of minimal scleral buckling.
The aim of this study was to investigate the outcomes of one "8"-shaped scleral suture of minimal scleral buckling (MSB) surgery without sub-retinal drainage for rhegmatogenous retinal detachment (RRD) treatment. Thirty patients (30 eyes) with RRD were recruited. Thirty eyes with RRD were repaired by one "8"-shaped scleral suture of minimal buckling without subretinal drainage by one surgeon. T...
متن کاملApplying Sutureless Encircling Number 41 Band and Transscleral Chandelier-Assisted Laser Retinopexy for Scleral Buckling Procedure
Purpose To assess the outcome of sutureless encirlcing number 41 band and transscleral laser retinopexy in uncomplicated rhegmatogenous retinal detachment (RRD), using a wide-angle viewing system (WAVS) and chandelier endoillumination. Methods Prospective intervention study included 30 eyes of 30 patients presenting with RRD of recent onset indicated for SB. All cases were treated by suturele...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: British Journal of Ophthalmology
سال: 1963
ISSN: 0007-1161
DOI: 10.1136/bjo.47.6.350