Dynamic hip screw blade fixation for intertrochanteric hip fractures.
PURPOSE To assess the one-year outcome of a dynamic hip screw (DHS) blade in the treatment of AO/OTA 31-A1 and 31-A2 intertrochanteric hip fractures. METHODS 35 men and 65 women aged 47 to 100 (mean, 83) years underwent fixation with a DHS blade for A1 (n=47) and A2 (n=53) intertrochanteric hip fractures after a low-energy injury. Patients were operated on within 48 hours of admission. Antero...
متن کاملAwareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip.
We compared the results of the surgical treatment of trochanteric hip fractures before and after surgeons had been introduced to the tip-apex distance (TAD) as a method of evaluating screw position. There were 198 fractures evaluated retrospectively and 118 after instruction. The TAD is the sum of the distance from the tip of the screw to the apex of the femoral head on anteroposterior and late...
متن کاملComparing Therapeutic Outcomes of Dynamic Hip Screw and Multiple Cannulated Screws as Internal Fixation in Femoral Neck Fractures
Background and purpose: Femoral neck fracture is associated with a high rate of side effects, especially in young people, who are usually affected by severe energy shocks. Results after injury depend on some factors, including displacement, fragility, bleeding rate, proper placement, and stable and strong fixation. The aim of this study was to compare dynamic hip screw (DHS) or multiple cannula...
متن کاملThe prognostic value of tip-to-apex distance (TAD index) in intertrochanteric fractures fixed by dynamic hip screw
Intertrochanteric fractures (ITFs) are the most common type of fractures requiring surgical intervention. They also have the highest surgical mortality among orthopedic operations. Among the many different techniques used for fixation of this type of fracture, use of the Dynamic Hip Screw (DHS) has gained wide acceptance. This current study was designed to assess positive predictive value of ti...
متن کاملSalvage of failed dynamic hip screw fixation of intertrochanteric fractures.
Twenty-six patients with failed dynamic hip screw fixation of intertrochanteric fractures were included in this study. The mean age of the patients was 61 years (range, 38-84 years). Average limb shortening was 2.4 cm; 18 patients were treated with revision internal fixation and eight patients with prosthetic replacement. The decision depended on the physiological age of the patient, quality of...