Synchrotron radiation-induced total reflection X-ray fluorescence analysis
Synchrotron radiation-induced total reflection X-ray fluorescence (SR-TXRF) analysis is a high sensitive analytical technique that offers limits of detection in the femtogram range for most elements. Besides the analytical aspect, SR-TXRF is mainly used in combination with angle-dependent measurements and/or X-ray absorption near-edge structure (XANES) spectroscopy to gain additional informatio...
متن کاملThe use of a portable total reflection X-ray fluorescence spectrometer for field investigation
A newly developed, portable total reflection X-ray fluorescence (TXRF) spectrometer was tested during a field campaign on Chilean lakes and a German river in January 2002. The field measurements were compared with laboratory measurements carried out on a stationary instrument in the German laboratory. For method validation certified reference material (NIST SRM 1640 Trace elements in natural wa...
متن کاملAluminum Impurities in Silicon: Investigation of X-ray Raman Scattering in Total Reflection X-ray Fluorescence Spectroscopy
Total Reflection X-ray Fluorescence (TXRF) using Synchrotron Radiation from the Stanford Synchrotron Radiation Laboratory (SSRL) has been used to study Al impurities on Si wafer surfaces. For primary excitation energies below the Si K absorption edge an inelastic resonance scattering due to resonant xray Raman scattering is observed. This scattering dominates the background behavior of the Al K...
متن کاملTotal Reflection X-ray Fluorescence Spectrometry for Characterization of Nuclear Materials
Total reflection X-Ray Fluorescence (TXRF) is a comparatively new technique of material characterization and trace element analysis. It is an advanced variant of Energy Dispersive X-ray Fluorescence (EDXRF) and is based on the principle of total reflection of X-rays when these radiations fall on a flat smooth surface at a grazing angle less than the critical angle of the sample support. The cri...
متن کاملSynchrotron Radiation Total Reflection X-ray Fluorescence - Spectroscopy for Microcontamination Analysis on Silicon Wafer Surfaces
As dimensions in state-of-the-art CMOS devices shrink to less than 0.1 pm, even low levels of impurities on wafer surfaces can cause device degradation. Conventionally, metal contamination on wafer surfaces is measured using Total Reflection X-Ray Fluorescence Spectroscopy (TXRF). However, commercially available TXRF systems do not have the necessary sensitivity for measuring the lower levels o...