A Review of LCC-HVDC and VSC-HVDC Technologies and Applications
نویسندگان
چکیده
منابع مشابه
Dynamic Harmonic Modeling and Analysis of VSC-HVDC Systems
Harmonics have become an important issue in modern power systems. The widespread penetration of non-linear loads to emerging power systems has turned power quality analysis into an important operation issue under both steady state and transient conditions. This paper employs a Dynamic Harmonic Domain (DHD) based framework for dynamic harmonic analysis of VSC-HVDC systems. These systems are wide...
متن کاملHVDC Connection of Offshore Wind Parks: VSC vs LCC with STATCOM
It is now clear that the installation of offshore wind parks is the next step towards an even more widespread use of wind power. In what concerns the interconnection of remote offshore wind parks to the existing onshore grid, for distances over 50 km and/or installed capacities above 100 MW, High Voltage Direct Current (HVDC) technology seems to be more adequate than High Voltage Alternating Cu...
متن کاملControlled Islanding with Vsc-hvdc Links Acknowledgements
Controlled islanding has been widely discussed in the literature as a novel concept for the power system protection. However, the islanding can result in unbalanced islands where the power mismatch will often cause an instability that can lead either to a subsequent load shedding or generator tripping within the islands. Controlled VSC-HVDC links can mitigate the negative consequences of the co...
متن کاملA Novel Topology of Hybrid HVDC Circuit Breaker for VSC-HVDC Application
Van-Vinh Nguyen 1, Ho-Ik Son 1, Thai-Thanh Nguyen 1 ID , Hak-Man Kim 1,2,* and Chan-Ki Kim 3 1 Department of Electrical Engineering, Incheon National University, 119 Academy-ro, Yeonsu-gu, Incheon 22012, Korea; nvvinh@inu.ac.kr (V.-V.N.); shi0617@inu.ac.kr (H.-I.S.); ntthanh@inu.ac.kr (T.-T.N.) 2 Research Institute for Northeast Asian Super Grid, Incheon National University, 119 Academy-ro, Yeo...
متن کاملDamping of Subsynchronous Resonance Using a Vsc-hvdc Link
A possible detrimental effect of onshore series compensation in the GB grid is the appearance of subsynchronous resonance (SSR). In this paper, a control scheme for a VSC-HVDC link capable of damping subsynchronous oscillations is proposed in order to effectively counteract the potential damage caused by SSR in steam turbines. The VSC-HVDC link has been modelled to maintain its primary function...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Transactions on Environment and Electrical Engineering
سال: 2016
ISSN: 2450-5730
DOI: 10.22149/teee.v1i3.29