A regenerative microchannel device for recording multiple single‐unit action potentials in awake, ambulatory animals
نویسندگان
چکیده
منابع مشابه
A regenerative microchannel device for recording multiple single-unit action potentials in awake, ambulatory animals.
Despite significant advances in robotics, commercially advanced prosthetics provide only a small fraction of the functionality of the amputated limb that they are meant to replace. Peripheral nerve interfacing could provide a rich controlling link between the body and these advanced prosthetics in order to increase their overall utility. Here, we report on the development of a fully integrated ...
متن کاملImproved technique for recording single unit activity in awake animals.
An improved system for recording the electrical activity of single neurons in the brain of awake, unanesthetized and unrestrained animals is described, including complete details of construction and use. The advantages of this new technique over earlier methods are discussed.
متن کاملImplantable electrode for recording nerve signals in awake animals.
An implantable electrode assembly consisting of collagen and metallic electrodes was constructed to measure simultaneously neural signals from the intact nerve and bioelectrical noises in awake animals. Mechanical artifacts, due to bodily movement, were negligibly small. The impedance of the collagen electrodes, measured in awake cats 6-7 days after implantation surgery, ranged from 39.8-11.5 k...
متن کاملA student apparatus for recording action potentials in cockroach legs.
A comparatively simple apparatus allows even beginning students to observe action potentials in the cockroach leg. The recordings are made extracellularly by impaling the leg on two insect pins. Deflection of large spines on the leg, which are each innervated by one sensory neuron, initiates the action potentials. Using this technique, students observe the all-or-nothing nature of action potent...
متن کاملTransmural recording of monophasic action potentials.
To investigate the possibility of transmural recording of repolarization through the ventricular wall, KCl monophasic action potential (MAP) electrodes positioned along plunge needles were developed and tested. The MAP electrode consists of a silver wire surrounded by agarose gel containing KCl, which slowly eluted into the adjacent tissue to depolarize it. In six dogs, a plunge needle containi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: European Journal of Neuroscience
سال: 2015
ISSN: 0953-816X,1460-9568
DOI: 10.1111/ejn.13080