A radiation detector fabricated from silicon photodiode.
نویسندگان
چکیده
منابع مشابه
Perforated diode neutron detector modules fabricated from high-purity silicon
Compact neutron detectors are being designed and tested for use as low-power real-time personnel dosimeters. The neutron detectors are pin diodes that are mass produced from high-purity Si wafers. Each detector has thousands of circular perforations etched vertically into the device. The perforations are backfilled with LiF to make the pin diodes sensitive to thermal neutrons. The prototype dev...
متن کاملGated Silicon Drift Detector Fabricated from a Low-Cost Silicon Wafer
Inexpensive high-resolution silicon (Si) X-ray detectors are required for on-site surveys of traces of hazardous elements in food and soil by measuring the energies and counts of X-ray fluorescence photons radially emitted from these elements. Gated silicon drift detectors (GSDDs) are much cheaper to fabricate than commercial silicon drift detectors (SDDs). However, previous GSDDs were fabricat...
متن کاملComparison of the current of UV ray radiation on PIN Silicon photodiode and Gallium Arsenide
The high-energy UV ray radiation on PIN Silicon photodiodes reduces the optimal parameters of these photodiodes. In this paper, by representing a model, we compare the effect of UV dose on the bright current in these two types of photodiodes and confirm the analytic relationships in order to simulate a model with the help of the Silvaco- Atlas software. In this model, Silicon photodiodes and Ga...
متن کاملCharacterization Of Pin Diode Silicon Radiation Detector
Bhabha atomic research centre has been exploring some of the unique features of silicon detector in a variety of nuclear structure experiment using high-energy photons and heavy ions projectiles. Current experimental application make use of large area silicon detector with depletion thickness of ~150-1000 μm. The low cost silicon detector shows excellent energy and position resolution. In this ...
متن کاملDouble-Layer Silicon PIN Photodiode X-Ray Detector for a Future X-ray Timing Mission
A double-layer silicon detector consisting of two 500μm-thick silicon PIN photodiodes with independent readouts was mounted in a vacuum chamber and tested with X-ray sources. The detector is sensitive from 1–30 keV with an effective area of 6 mm. The detector performs best at −35 ◦C with an energy resolution of 220 eV (FWHM, full width at half maximum) at 5.9 keV, and is able to operate at room...