A quantitative stopped-flow fluorescence assay for measuring polymerase elongation rates

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A quantitative fluorescence‐based steady‐state assay of DNA polymerase

Fluorescent dyes that bind DNA have been demonstrated as a useful alternative to radionucleotides for the quantification of DNA and the in vitro measurement of the activity of DNA polymerases and nucleases. However, this approach is generally used in a semi-quantitative way to determine relative rates of reaction. In this report, we demonstrate a method for the simultaneous quantification of DN...

متن کامل

A Quantitative Fluorescence-Based Lipase Assay

An easy and fast gel diffusion assay for detecting and monitoring lipase activity by quantification of fluorescein is described. By measuring the intensity of fluorescein, it is possible to obtain a calibration curve with a regression coefficient better than by using the radius of fluorescent haloes. Through the quantification of fluorescence intensity of fluorescein released after the hydrolys...

متن کامل

A real-time fluorescence assay for measuring N-dealkylation.

A real-time fluorescence assay system using a series of 9-N-(alkylamino)acridine derivatives (methyl, ethyl, n-propyl, n-butyl, n-pentyl, and benzyl) that are N-dealkylated to 9-aminoacridine (9AA) is described. The product, 9AA, is approximately 27-fold more fluorescent than the substrates using excitation and emission wavelengths of 405 and 455 nm, respectively. Tests using expressed CYP1A1, ...

متن کامل

Fluorescence-based, high-throughput DNA polymerase assay.

The commonly used DNA polymerase assay is based on the detection of incorporated radiolabeled nucleotides in a DNA elongation reaction. It is laborious, radioactive, and can be highly variable. Here we report a nonradioactive fluorescence-based assay. The method consists of Cydye-labeled nucleotides, biotinylated primer, and a streptavidin-coated microplate. The assay is found to have sensitivi...

متن کامل

A Novel Stopped-Flow Assay for Quantitating Carbonic-Anhydrase Activity and Assessing Red-Blood-Cell Hemolysis

We report a novel carbonic-anhydrase (CA) assay and its use for quantitating red-blood-cell (RBC) lysis during stopped-flow (SF) experiments. We combine two saline solutions, one containing HEPES/pH 7.03 and the other, ~1% CO2/44 mM [Formula: see text]/pH 8.41, to generate an out-of-equilibrium CO2/[Formula: see text] solution containing ~0.5% CO2/22 [Formula: see text]/pH ~7.25 (10°C) in the S...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Analytical Biochemistry

سال: 2009

ISSN: 0003-2697

DOI: 10.1016/j.ab.2009.04.035