A quantitative real-time PCR method for absolute telomere length
نویسندگان
چکیده
منابع مشابه
A novel method for real time quantitative RT-PCR.
A novel approach to quantitative reverse transcriptase polymerase chain reaction (QC RT-PCR) using real time detection and the 5' nuclease assay has been developed. Cystic fibrosis transmembrane transductance regulator (CFTR) target mRNA is reverse transcribed, amplified, detected, and quantitated in real time. A fluorogenic probe was designed to detect the CFTR amplicon. Relative increase in 6...
متن کاملValidation of a quantitative method for real time PCR kinetics.
Real time RT-PCR is the most sensitive method for quantitation of gene expression levels. The accuracy can be dependent on the mathematical model on which the quantitative methods are based. The generally accepted mathematical model assumes that amplification efficiencies are equal at the exponential phase of the reactions for the same amplicon. However, no methods are available to test the ass...
متن کاملQuantitative Real-Time PCR
Unlike classical end-point analysis PCR, real-time PCR provides the data required for quantification of the target nucleic acid. The results can be expressed in absolute terms by reference to external quantified standards or in relative terms compared to another target sequence present within the sample. Absolute quantification requires that the efficiency of the amplification reaction is the s...
متن کاملReal time quantitative PCR.
We have developed a novel "real time" quantitative PCR method. The method measures PCR product accumulation through a dual-labeled fluorogenic probe (i.e., TaqMan Probe). This method provides very accurate and reproducible quantitation of gene copies. Unlike other quantitative PCR methods, real-time PCR does not require post-PCR sample handling, preventing potential PCR product carry-over conta...
متن کاملReal-time quantitative PCR.
Those who have worked in the field of quantitative polymerase chain reaction (PCR) since the early 1990s have accepted many of the tedious aspects of the early assays as routine. Difficulties associated with early quantitative PCR techniques included: (i) ensuring that the PCR was within the linear range of amplification (that portion where the PCR signal is directly proportional to the input c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BioTechniques
سال: 2008
ISSN: 0736-6205,1940-9818
DOI: 10.2144/000112761